DIPSWITCH SETTINGS

Most installations will not require any changes to the dipswitch settings. The factory default and
specialized dipswitch settings are indicated below.

Factory Default Settings:

Dipswitches ON:

1, 3 & 4

Horizontal Position Control:

Enabled

Signal Format:

RGBHV

Monitor Emulation at Power Up:

Enabled

Autoswitch:

Enabled


The following table lists the functions of the 6 dipswitches:

DIPSWITCH

FUNCTION

SETTING

1

Horizontal Position Control

On = Enabled*
Off = Disabled

2

Output Sync Format
(sync on green)

On = RGsB
Off = RGBS / RGBHV*

3

Output Sync Format
(RGBS or RGBHV)

On = RGBHV*
Off = RGBS

4

Monitor Emulation
at power up

On = Enabled*
Off = Disabled

5

Autoswitch

On = Disabled
Off = Enabled*

6 Reserved

* Factory Default Setting

MONITOR EMULATION

The factory default setting for the CIA112 is Monitor Emulation enabled. If the application requires
a local monitor,
make sure that the front panel Monitor Emulation LED is OFF (press the MONITOR
EMULATION Button to toggle between enabled / disabled). If no local monitor is necessary, make
sure the Monitor Emulation LED is ON.

OPTIMAL SETTINGS FOR LCD / DMD / D-ILA / PLASMA DISPLAYS

Output Sync Format - CIA100 Series Interfaces feature advanced sync processing circuitry that
offers superb compatibility with a wide range of display devices. The CIA112 has been designed
(and extensively tested) to provide excellent operation when set for RGBHV, RGBS and RGsB
output signal formats. However, some display devices most readily identify and display VGA-
type signals when they are in the RGBHV signal format. For this reason, users may achieve
optimal compatibility and more consistent results when the interface is set to the factory default
output sync format of RGBHV (see the Dipswitch Settings section above).

Horizontal Position Control - The CIA112 horizontal position control utilizes a new circuit
design that provides excellent image quality and greatly enhanced compatibility with a variety of
data display technologies. However, in rare cases, instability in parts of the displayed image may
still occur (depending on the design of the display device’s sync circuitry). Adjusting the data
display’s fine phase or auto phase adjustment will usually alleviate the problem. If problems
persist, users may wish to disable the CIA112 horizontal position control (dipswitch 1 = off).