Communication protocol Serie30

Page 8/37

3.3.2.2 Exception errors
The message has been received correctly (no transmission error has occurred), but the transmitted function number and/or the

parameters are invalid. The slave responds with an exception error, unless the message has been received in broadcasting

mode.

The message transmitted as a response by the slave has the following format:

DevAddr

1

Function

code

Exception

code

KELLER:CRC16_H

MODBUS:CRC16_L

KELLER:CRC16_L

MODBUS:CRC16_H

4 types of exception errors are defined :

non-implemented function

1

incorrect parameters

2

erroneous data

3

initialisation (only KELLER bus)

32

Exception error 32 occurs when the device is started up anew and initialisation has not been carried out. This happens every

time the device is connected anew after a break in the power supply.

only MJK bus

again