beautypg.com

System parameter setting – AVSL Citronic DSM2-6 User Manual

Page 8

background image

8

170.660UK User Manual



5. Press the encoder to confirm value and rotate encoder to move over to Gain

6. Press the encoder to confirm Gain and rotate encoder to adjust the Slope/Bandwidth value

7. Press the encoder to confirm Slope/Bandwidth

A short press of the EQ function button switches through EQ1 to EQ6 to set each EQ

Press and hold MUTE/EDIT key of other channels to repeat process for each in turn

System Parameter Setting

All system settings can be stored in the internal memory of the DSM2-6 mkIII. These functions are edited in a similar

way to the input/output channel functions. Pressing the relevant function key opens the current status in the LCD display
and these values may be adjusted using the rotary encoder and saved.

1. Load function:

[Parameter] Load channel settings from one of the 30 internal programs

example:

1. Press LOAD and the display will show as below

2. Turn encoder clockwise to select the required program and press to confirm

Channel settings will now all be set as per the selected program

2. Save function:

[Parameter] Save current channel settings to one of the 30 internal programs

example:

1. Press SAVE and the display will show as below

2. Turn encoder clockwise to select the required program and press to confirm

3. Rotate the encoder to select a letter and press to move onto the next character

4. Repeat the above process until the program name is complete

5. Press and hold the encoder for 3secs to save the program with the selected name

Channel settings will now all be saved to the selected program

6. Press the encoder to confirm value and rotate encoder to move over to next input
7. Press the encoder to select the input to switch on or off and rotate encoder to select