AVSL Citronic DSM2-6 User Manual
Page 14
14
170.660UK User Manual
Input Edit Screen
1. Input Delay setting
Click “ms” button to select units - milliseconds (ms), feet (ft), metres (m)
Range 0-1000ms or equivalent in distance
2. Input Polarity setting
Click “Polarity” button to select polarity (+/-)
Output Edit Screen
1. Output Gain setting
Virtual Gain control can be adjusted from -12dB to +12dB in 0.1dB steps
2. Output Delay setting
Click “ms” button to select units - milliseconds (ms), feet (ft), metres (m)
Range 0-1000ms or equivalent in distance
3. Output Polarity setting
Click “Polarity” button to select polarity (+/-)
4. X-OVER setting
HPF and LPF curves can be clicked and dragged on the frequency graph
Alternatively, frequency can be entered in the “Freq” fields
Filter type can be change by clicking the “Type” button
Slope can be adjusted by clicking the “Slope” button
5. Limiter setting
“Threshold” value is the level at which the limiter takes effect (dBu)
“Attack” is the speed at which the limiter acts upon the signal
“Release” is the ratio of attack speed at which the limiter stops acting