170.660UK User Manual
5. X-OVER setting:
[Parameter] X-OVER
Independent HPF and LPF per channel
Frequency 20Hz - 20kHz Type Linkwitz-Riley, Bessel, Butterworth
Slope 12/18/24/48dB per octave
example:
1. Hold IN A MUTE/EDIT button 3secs for edit mode (green LED lit)
2. Press X-OVER and the LPF display will show as below
3. Turn encoder anticlockwise to open the Freq setting and adjust value
4. Press the encoder to confirm value and rotate encoder to move over to Filter Type
5. Press the encoder to confirm Filter Type and rotate encoder to select the Slope
6. Press the encoder to confirm Slope and rotate encoder to adjust the value
7. Press X-OVER function button and the display will switch to HPF screen
8. Turn encoder clockwise to open the Freq setting and adjust value
9. Press the encoder to confirm value and rotate encoder to move over to Filter Type
10. Press the encoder to confirm Filter Type and rotate encoder to select the Slope
11. Press the encoder to confirm Slope and rotate encoder to adjust the value
6. EQ setting:
[Parameter] Output EQ1 – EQ6 (6 independent EQs for each channel)
Parametric mode:
Frequency 20Hz - 20kHz Gain -20 - +20dB Bandwidth 0.05Oct - 3Oct
Shelving mode: (Hi Shelf, Lo Shelf)
Frequency 20Hz - 20kHz Gain -20 - +20dB Slope +6 or +12dB/octave
example:
1. Hold OUT 1 MUTE/EDIT button 3secs for edit mode (green LED lit)
2. Press EQ and the display will show as below
3. Turn encoder to select EQ type – PEQ (parametric), Lo Shelf, Hi Shelf
4. Press the encoder to confirm type and rotate encoder to move the Freq