III. INSTALLATION
The heatsinks shown in this manual are for reference purposes only. The recom-
mended heatsinks for the Pentium II processor are those with three-pin fans that can
be connected to the CPU fan connector on the motherboard. These heatsinks have
the added benefits of proper heat dissipation and with the hardware monitor, the
ability to monitor the fan’s RPM and use the alert function through the included
LANDesk Client Manager (LDCM) software.
AAVID Heatsink
The procedures for installing the AAVID heatsink with fan is similar to those of the
heatsink without a fan. You will not, however, be able to use the heatsink support top
bar because of the fan. The heatsink support top bar will, however, still be included
in the package, in case you use a heatsink without a fan.
Elan Vital Heatsink
The procedures for installing the Elan Vital heatsink with fan is also similar to those of
the heatsink without a fan. The Elan Vital heatsink, however, comes with a lever to
clamp the heatsink into the SEC cartridge. Mount the heatsink in the orientation as
shown then flip the lever from “Unlock” to “Lock”. You will also not be able to use the
heatsink support top bar because of the fan. The heatsink support top bar will, how-
ever, still be included in the package, in case you use a heatsink without a fan.