OSRAM DIM MCU User Manual

Dim mcu, Manual control unit fitting instructions, Description

background image

OSRAM GmbH

Kunden Service Center

Customer-Service-Center (CSC)
Steinerne Furt 62

86167 Augsburg

Germany
Tel : +49 (0) 1803 677 - 200

(kostenpflichtig / charges apply)

Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de

40503003474246

4050300347424

Manual control unit

Fitting instructions

IV 2009
DIM_MCU_ma0904en_we1.01.indd

DIM MCU

+ – L

C

D

A

B

Description

Purpose and application

The DIM MCU electronic potentiometer (manual control unit)

controls up to 50 dimmable electronic control gears and enables

the manual brightness control of luminaires.
The potentiometer is mounted in flush device boxes.

Function

The potentiometer converts rotations of and pressure on the

rotary knob into 1...10V voltage signals, which are transmitted

to the dimmable electronic control gears.

Design

The potentiometer is made up of the following components:
• Rotary potentiometer (A)
• Connections (C)

– Control lines (+, –)

– Dimmed + switched phase (↓)

– Phase (L)

– Trimmer (B)

• Housing with rotary knob (D)

Installation

Safety instructions

The potentiometer must only be installed and put into operation

by a qualified electrician. The applicable safety regulations and

accident prevention regulations must be observed.

WARNING!
Exposed, live cables.
Danger of electric shock!
• Only work on the potentiometer when it is de-

energised.

CAUTION!
Destruction of the potentiometer and other devices

through incorrect mounting!
• The potentiometer is designed for mounting in

flush device boxes. If mounted elsewhere, provi-

deadequate cable strain relief and insulation.

• Do not wire the control line with an external volt-

age, especially not a mains voltage of 230 V.

• Do not exceed the maximum number of ECGs.

Continued on the back page!