Appendix

Technical data

Operating voltage

220-240 V/50-60 Hz

(no DC operation)

Fuse

External 6 A (10 A)

Power consumption

Switched on: Approx. 1 W

Switched off: Approx. 0.7 W

Maximum total line

length

100 m

Switch output

Floating contact (internal relay, make

contact)

Switch output load

capacity

Resistive load: 10 A/250 V AC,

6 A/30 V DC

Ohmic lamp load: 5 A
Inductive load: 5 A
30 x single-lamp ECG 18 W

20 x two-lamp ECG 18 W
30 x single-lamp ECG 36 W

20 x two-lamp ECG 36 W
20 x single-lamp ECG 58 W

10 x two-lamp ECG 58 W

Detection area

Max. Ø 12 m

Installation height

Max. 5 m (ideal: 2.5 - 3 m)

Switching hysteresis

Approx. 15%

Operating temperature

0 °C ... +50 °C

Protection class

II

Protection type

IP 20

Weight

Approx. 150 g

Dimensions (L x W x H)

58.5 x 70.5 x 47 mm

Dimensioned drawing

Conformity with the relevant EU directives is

confirmed by the CE symbol.