2 baud rate, 3 data bits, stop bits, parity – SENA PS400 User Manual
Page 44

44
Figure 4-16. Set up Serial communication type
4.2.2 Baud rate
The valid baud rate for the HelloDevice Pro Series is as follows.
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600 and 115200
The baud rate can be changed by selecting the menu of Serial port configuration-UART
configuration–Baud rate
.
---------------------------------------------------------------------------
Serial configuration --> port#1 ---> UART
---------------------------------------------------------------------------
Select menu
1. Type : RS232
2. Baud rate : 9600
3. Data bits : 8
4. parity : None
5. Stop Bits : 1
6. Flow control : Hardware
7. DTR behavior : Always High
8. DSR behavior : None
-----> 2
Select baud rate
1 = 1200, 2 = 2400, 3 = 4800, 4 = 9600
5 = 19200, 6 = 38400, 7 = 57600, 8 = 115200
----->
Figure 4-17. Set up the baud rate
4.2.3 Data bits, Stop bits, Parity
The factory default setting of the data bits, stop bits and parity are 8, 1 and None. They can be
changed using the menu 3, 4 and 5.
---------------------------------------------------------------------------
Serial configuration --> port#1 ---> UART
---------------------------------------------------------------------------
Select menu
1. Type : RS232
2. Baud rate : 9600
3. Data bits : 8
4. parity : None
5. Stop Bits : 1
6. Flow control : Hardware
7. DTR behavior : Always High
8. DSR behavior : None
-----> 3 (or 4 or 5)
Select data bits (1 = 7 bits, 2 = 8 bits) :
(Or
Select parity (1 = None, 2 = Even, 3 = odd) :
Select stop bits (1 = 1 bit , 2 = 2 bits) :