3) Parameters
Remote IP address (or domain name) and Remote Port
This is the information on the remote host to which the HelloDevice Pro Series will try to connect
in TCP client mode. The IP address (or domain name) should be specified together with the TCP
port number. To specify the information on the remote host, select menu 2 on the TCP Client
mode configuration screen. The format of remote host information is as follows.
[IP address (or domain name)]:[TCP Port number]
e.g.)
211.116.20.197:1221
: IP address 211.116.20.197, Port 1221
ser.sena.com:6001
: domain name ser.sena.com, Port 6001
---------------------------------------------------------------------------
serial configuration -->port#1 --> TCP/IP
---------------------------------------------------------------------------
Select menu
1. Host mode : TCP Client
2. Destination IP & port : 192.168.1.120:6010
3. Cyclic connection : Disable
-----> 2
Enter destination IP and port (ex: 192.168.1.1:7001)
-----> 192.168.1.200:6001
---------------------------------------------------------------------------
serial configuration -->port#1 --> TCP/IP
---------------------------------------------------------------------------
Select menu
1. Host mode : TCP Client
2. Destination IP & port : 192.168.1.200:6001
3. Cyclic connection : Disable
----->
Figure 4-7. Set up remote host information
Cyclic connection interval
This is the time interval at which the HelloDevice Pro Series will try to connect to the remote host
regardless of the existence of incoming data from the serial port. If the interval is specified with a
valid value other than 0, the function is enabled. The time interval will be the specified value by
the unit of minute. To specify the interval, select menu 3 on the TCP Client mode configuration
screen.