Ip address configuration, 1 static ip – SENA LS100W User Manual
Page 27

27
4: IP Address Configuration
A valid IP address of the LS100W needs to be assigned before it starts to work in the user's network
environment.
A network system administrator may provide the user with this IP address setting
information for the network. The IP address must be unique within the network. Otherwise, the
LS100W will not have a valid connection to the network.
Users can choose the desired IP mode out of the two IP operating modes, i.e., Static IP and DHCP.
The factory default IP mode is DHCP mode. Table 4-1 shows the parameter items for IP configuration.
Table 4-1. IP configuration parameters
IP address
Subnet mask
Static IP
Default gateway
DHCP
No parameters required
Basic ‘set’command usage for IP configuration is as follows:
set ip ipmode par1 par2 ...
where,
ipmode: ‘static’for Static IP / ‘dhcp’for DHCP
parameters:
if ipmode = static,
par1 = IP address, par2 = subnet mask, par3 = gateway
if ipmode = dhcp,
no parameters required
4.1 Static IP
4.1.1 Overview
In the Static IP mode, users have to manually specify all the parameters such as IP addresses of the
LS100W, valid subnet mask and the default gateway IP address.