4 command usage – SENA LS100W User Manual
Page 16
![background image](/manuals/292704/16/background.png)
16
Type the following command in the command line interface of your computer.
telnet 192.168.1.254
Or run a telnet program with parameters as follows.
Figure 2-7 Telnet program set up example
2)
The user has to log into the LS100W. Type the user name and password. A factory default
setting of the user name and password are both admin.
3)
If the user logs into the LS100W successfully, the same command prompt screen as the
serial console will be displayed. The user can set, get, save configuration parameters and
exit console, reboot the device as like the serial console.
4)
If serial console or the other remote consoles are connected already, new console will not be
established at all.
2.4 Command Usage
The LS100W provides several simple commands for configuration and control of the LS100W. Table
2-2 summarizes command set which LS100W supports.
Table 2-2 LS100W command set summary
Command
Description
Result
set group par1 [par2 ...] +
Set configuration parameters
- group = 'ip', 'host', 'serial' or 'admin'
- par1 ... = configuration parameters. Use * to
keep a parameter's value
If success,
“OK”+
If error
“ERROR” +
get [group] +
Get configuration parameter values
- group = 'ip', 'host', 'serial', 'admin' or 'status'
- If group is specified, shows settings of the
group.
- If group is omitted, shows settings of all groups.
Parameter value display
help [group] +
Shows command usage screen.
Help message display