Littelfuse K2xx0yHU Series User Manual
K2xx0yhu series, Teccor, Brand thyristors
![background image](/manuals/292335/1/background.png)
1
Revised: 01/06/14
Specifications are subject to change without notice.
©2014 Littelfuse, Inc
Teccor
®
brand Thyristors
High Energy Unidirectional SIDACs
K2xx0GHURP Series
K2xx0yHU Series
Description
The new K2xx0yHU is a higher energy SIDAC switch for gas
ignition applications requiring higher current pulse current
especially at low repetition rate. It is offered in a DO-15
leaded package and DO-214AA surface mount package.
Voltage activation of this solid state switch is accomplished
with peak voltage level of 190 to 260Volts. The SIDAC is
a silicon bilateral voltage triggered Thyristor switch that
switches on through a negative resistance region to a low
on-state voltage. Conduction will continue until current is
interrupted or lowered below minimum holding current of
the device.
Features
Electrical Specifications
(T
J
= 25°C, unless otherwise specified)
Symbol
Parameters
Test Conditions
Min
Max
Unit
V
BO
Breakover/Trigger Voltage
K2000yHU
190
210
V
K2200yHU
210
230
K2400yHU
230
250
K2500yHU
240
260
V
DRM
Repetitive Peak Off-state Voltage
K2000yHU
180
V
K2200yHU
190
K2400yHU
210
K2500yHU
220
I
T(RMS)
On-state RMS Current
50/60Hz, T
J
< 125°C
1
A
V
TM
Peak On-state Voltage
I
T
= 1A
1.5
V
I
H
Dynamic Holding Current
R
L
= 100Ω
50/60Hz Sine Wave
60
mA
R
S
(V
BO
– V
S
)
Switching Resistance, R
S
= ________
(I
S
– I
BO
)
50/60Hz Sine Wave
100
Ω
I
BO
Breakover Current
50/60Hz Sine Wave
500
μA
I
TRM
Peak Repetitive Pulse Current
(refer to figure 4)
t
p
= 10μs
60Hz
120
A
5Hz
280
di/dt
Critical Rate of Rise of On-State Current
220
A/μs
dv/dt
Critical Rate of Rise of Off-State Voltage
1500
V/μs
T
S
Storage Temperature Range
-40
150
°C
T
J
Junction Temperature Range
-40
125
°C
R
θJL
Thermal Resistance, Junction to Lead
DO-15
18
°C/W
DO-214AA
30
R
θJA
Thermal Resistance, Junction to Ambient
DO-15
75
°C/W
Schematic Symbol
Applications
Suitable for high voltage power supplies, natural gas
igniters, and Xenon flash ignition.
• AC circuit oriented
• Triggering Voltage of 190
to 260V
• 280A Pulse current
capability
• RoHS compliant
• Unidirectional
Note: xxx - voltage, y = package
K
A