Sidactor, Protection thyristors, Teccor – Littelfuse SDP Series SOT23-5 User Manual
Page 2: Brand sidactor, Dsl protection devices, The epoxy meets ul 94v-0 ratings

SIDACtor
®
Protection Thyristors
2
Revised: August 6, 2013
© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com for current information.
Teccor
®
brand SIDACtor
®
DSL Protection Devices
Parameter Name
Symbol
Test Conditions
Value
Units
Lightning surge waveforms
I
pp
8x20µs
50
A
min
max
Operating Free Temperature Range
T
A
-40
+85
°C
Junction temperature
T
J
-40
+150
°C
Storage temperature
T
STG
-40
+150
°C
Maximum Ratings
Notes:
- The device also complies with IEC 61000-4-2 ESD ±15kV (air discharge), ±8 kV(contact discharge) and IEC 61000-4-4 EFT 40A(5/50nS) in equipment level ESD test when used behind the
xDSL transformer.
- The device must initially be in thermal equilibrium with -40°C < T
J
< +150°C
Mechanical dimensions, recommended layout dimensions
E
B
D
A
A2
A1
C
F
G
0.138(3.5)
0.047(1.2)
0.037(0.95)
0.024(0.60)
0.037(0.95)
Dimension are in inches
(and millimeters).
Dimension
Inches
Millimeters
Min
Max
Min
Max
A
0.035
0.057
0.90
1.45
A1
0
0.004
0
0.10
A2
0.035
0.051
0.90
1.30
B
0.014
0.020
0.35
0.50
C
0.004
0.008
0.09
0.20
D
0.11
0.118
2.80
3.00
E
0.059
0.069
1.50
1.75
F
0.102
0.118
2.6
3.00
G
0.004
0.024
0.10
0.60
The epoxy meets UL 94V-0 ratings
.
- The lightning surge may be repeated after the device returns to its initial conditions.