beautypg.com

Tvs diode arrays, General purpose esd protection - sp724 series, Diodes) – Littelfuse SP724 Lead-Free_Green Series User Manual

Page 3

background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.
Revised: 11/25/13

TVS Diode Arrays

(SPA

®

Diodes)

General Purpose ESD Protection - SP724 Series

ESD Capability

ESD rating is dependent on the defined test standard. The
evaluation results for various test standards and methods
based on Figure 1 are shown in Table 1.3

The SP724 has a Level 4 rating when tested to the IEC
61000-4-2 Human Body Model (HBM) standard and
connected in a circuit in which the V+ and V- pins have
a return path to ground. Level 4 specifies a required
capability greater than 8kV for direct discharge and greater
than 15kV for air discharge.

The “Modified” MIL-STD-3015.7 condition is defined as an
“in-circuit” method of ESD testing, the V+ and V- pins have
a return path to ground.The SP724 ESD capability is greater
than 8kV with 100pF discharged through 1.5kΩ. By strict
definition of the standard MIL-STD-3015.7 method using
“pin-to-pin” device testing, the ESD voltage capability is
greater than 2kV.

For the SP724 EIAJ IC121 Machine Model (MM) standard,
the ESD capability is typically greater than 1.8kV with
200pF discharged through 0kΩ.

The Charged Device model is based upon the self-
capacitance of the SOT-23 package through 0kΩ.

Standard

Type/Mode

R

D

C

D

±V

D

IEC 61000-4-2

(Level 4)

HBM, Air Discharge

330 Ω 150pF

15kV

HBM, Direct Discharge 330 Ω 150pF

8kV

MIL-STD-3015.7

Modified HBM

1.5k Ω 100pF 8kV †

Standard HBM

1.5k Ω 100pF

2kV

EIAJ IC121

Machine Model

0k Ω

200pF

400V

US ESD DS 5.3

Charged Device

Model

0k Ω

NA

3kV

H.V.

SUPPLY

V

D

IN

DUT

C

D

R

1

IEC 1000-4-2: R

1

50 to 100M

R

D

CHARGE

SWITCH

DISCHARGE

SWITCH

MIL STD 3015.7: R

1

1 to 10M

FIGURE 1. ELECTR OSTATIC DISCHARGE TEST

†Upper limit of laboratory test set.

600

800

1000

1200

200

160

120

80

40

0

SINGLE PULSE

T

A

= 25°C

FORWARD SCR VOLTAGE DROP (mV)

FOR

W

ARD SCR CURRENT (mA)

5

4

3

2

1

0

T

A

= 25°C

SINGLE PULSE

EQUIV. SAT. ON
THRESHOLD ~ 1.1V

FORWARD SCR VOLTAGE DROP (V)

0

1

2

3

FO

RW

ARD SCR CURRENT (A

)

600

800

1000

1200

200

160

120

80

40

0

SINGLE PULSE

T

A

= 25°C

FORWARD SCR VOLTAGE DROP (mV)

FOR

W

ARD SCR CURRENT (mA)

5

4

3

2

1

0

T

A

= 25°C

SINGLE PULSE

EQUIV. SAT. ON
THRESHOLD ~ 1.1V

FORWARD SCR VOLTAGE DROP (V)

0

1

2

3

FO

RW

ARD SCR CURRENT (A

)

Figure 1: Electrostatic Discharge Test

Table 1: ESD Test Conditions

Figure 3: High Current SCR Forward Voltage Drop Curve

Figure 2: Low Current SCR Forward Voltage Drop Curve

This manual is related to the following products: