Lcp fused coordination panel, Pre-engineered solution datasheet, Selective coordination panel – Littelfuse LCP Fused Coordination PaneL User Manual

Page 2: Dimensions mm (inches)

background image

Pre-Engineered Solution Datasheet

Littelfuse.com

© 2013 Littelfuse POWR-GARD

®

Products

Rev: 011113

2 of 3

LCP Fused Coordination PaneL

Selective Coordination Panel

Inner Line

GND Bus

Neutral Detail

Neutral Detail

(6 AWG - 300 kcmil) Cu/Al

Incoming Main Lugs

Cutler Hammer

GHB (480 V) or BAB (208 V)

Circuit Breakers

(or Pullouts)

LPSC001ID POWR-Safe

Dead front Class CC 600 VAC

Fuseholder for use with Littelfuse

CCMR, KLKR or KLDR Class CC fuses

or POWR-Safe LPSJ holders for use

the Class J fuses. (Fuses not included)

LPSC001ID POWR-Safe

Dead front Class CC 600 VAC

Fuseholder for use with Littelfuse

CCMR, KLKR or KLDR Class CC fuses

or POWR-Safe LPSJ holders for use

the Class J fuses. (Fuses not included)

Front Trim

Type 1 (NEMA) Enclosure

Front View with Front Removed

Hinged Door with

Catch and Lock

Dimensions in mm [inches]

Dimensions in mm [inches]

GND Bus

Inner Line

(6 AWG - 300 kcmil) Cu/Al
Incoming Main Lugs

Cutler Hammer

GHB (480 V) or BAB (208 V)

Circuit Breakers

(or Pullouts)

Front Trim

Type 1 (NEMA) Enclosure

Front View with Front Removed

Hinged Door with

Catch and Lock

[6.00]

152.4

[6.00]

152.4

[28.00]

711.2

[28.00]

711.2

[36.00]

914.4

[24.00]

609.6

[16.50]

419.1

[28.00]

711.2

[42.00]

1066.8

[30.00]

762

[16.50]

419.1

[9.69]

246.06

[8.94]

227.01

[28.00]

711.2

[9.69]

246.06

[8.94]

227.01

Dimensions mm (inches)

Standard Coordination Panel Board (up to 30 circuits)

Standard Coordination Panel Board (31-42 circuits)

Inner Line

GND Bus

Neutral Detail

Neutral Detail

(6 AWG - 300 kcmil) Cu/Al

Incoming Main Lugs

Cutler Hammer

GHB (480 V) or BAB (208 V)

Circuit Breakers

(or Pullouts)

LPSC001ID POWR-Safe

Dead front Class CC 600 VAC

Fuseholder for use with Littelfuse

CCMR, KLKR or KLDR Class CC fuses

or POWR-Safe LPSJ holders for use

the Class J fuses. (Fuses not included)

LPSC001ID POWR-Safe

Dead front Class CC 600 VAC

Fuseholder for use with Littelfuse

CCMR, KLKR or KLDR Class CC fuses

or POWR-Safe LPSJ holders for use

the Class J fuses. (Fuses not included)

Front Trim

Type 1 (NEMA) Enclosure

Front View with Front Removed

Hinged Door with

Catch and Lock

Dimensions in mm [inches]

Dimensions in mm [inches]

GND Bus

Inner Line

(6 AWG - 300 kcmil) Cu/Al
Incoming Main Lugs

Cutler Hammer

GHB (480 V) or BAB (208 V)

Circuit Breakers

(or Pullouts)

Front Trim

Type 1 (NEMA) Enclosure

Front View with Front Removed

Hinged Door with

Catch and Lock

[6.00]

152.4

[6.00]

152.4

[28.00]

711.2

[28.00]

711.2

[36.00]

914.4

[24.00]

609.6

[16.50]

419.1

[28.00]

711.2

[42.00]

1066.8

[30.00]

762

[16.50]

419.1

[9.69]

246.06

[8.94]

227.01

[28.00]

711.2

[9.69]

246.06

[8.94]

227.01

Note: The Littelfuse LPS, LPMP and LCP products are custom
designed products that fall outside standard specifications.

Dimensions may change depending on panel components.
More specialized configurations are also available.