beautypg.com

Littelfuse 216 Series User Manual

Axial lead & cartridge fuses

background image

© 2014 Littelfuse, Inc.

Specifications are subject to change without notice.

Revised: 01/31/14

Axial Lead & Cartridge Fuses

5×20 mm > Fast-Acting > 216 Series

216 Series, 5×20 mm, Fast-Acting Fuse

Agency Approvals

Agency

Agency File Number

Ampere Range

PS

E

Cartridge Certificates:

1-5A

NBK 080205-E10480A

6.3A-10A NBK 250702-E10480E

12.5A

NBK 240108-JP1021C

16A

NBK 240108-JP1021E

Leaded Certificates:

1-5A

NBK 080205-E10480B

6.3A-10A NBK 250702-E10480F

12.5A

NBK 240108-JP1021D

16A

NBK 240108-JP1021F

1A – 16A

Certificates:

2003010207079960

50mA – 6.3A

Certificates:

SU05001-2013

1A – 10A

Recognised File:

E10480

Guide:

JDYX2

50mA – 10A

12.5A, 16A

File:

029862

Acc. Class:

LR1422-30

File:

1027156

1309491

1117973

1020822

1027014

50mA – 125mA

160mA – 800mA

1A – 6.3A

8A – 10A

16A

License:

40013834

50mA – 6.3A

*8A, *10A

License:

40016442

*12.5A

License:

KM41462

1A – 6.3A

50mA – 16A

Features

• Designed to International

(IEC ) Standards for use
globally

• Meets the IEC 60127-2,

sheet 1 specification for
fast-acting fuses

• Available in cartridge and

axial lead form

• RoHS compliant and

lead-free

Applications

Electrical Characteristics for Series

% of Ampere

Rating

Ampere Rating

Opening Time

150%

50mA – 4A

60 minutes, Minimum

5A – 6.3A

60 minutes, Minimum

8A – 16A

30 minutes, Minimum

210%

50mA – 4A

30 minutes, Maximum

5A – 6.3A

30 minutes, Maximum

8A – 16A

30 minutes, Maximum

275%

50mA – 4A

0.01 sec.., Min.; 2 sec. Max.

5A – 6.3A

0.01 sec.., Min.; 3 sec. Max.

8A – 16A

0.04 sec., Min.; 20 sec. Max.

400%

50mA – 4A

.003 sec., Min.; 0.3 sec. Max.

5A – 6.3A

.003 sec., Min.; 0.3 sec. Max.

8A – 16A

.01 sec.., Min.; 1.0 sec. Max.

1000%

50mA – 4A

.02 seconds, Maximum

5A – 6.3A

.02 seconds, Maximum

8A – 16A

.03 sec.onds, Maximum

*Approval for Cartridge versions only

5×20mm fast-acting ceramic body cartridge fuse designed
to IEC specification.

Used as supplementary protection in appliance or
utilization equipment to provide individual protection for
components or internal circuits.

PS

E

Description

Additional Information

Datasheet

Samples

Resources