Diagram #6, Diagram #4, Diagram #5 – Derale Performance High Output 17" Electric Fan__Black Steel Shroud Kit User Manual

Page 2

background image

Derale Performance, Los Angeles, CA

800.421.6288 www.derale.com

OPTIONAL

MOUNTING

Fan Shroud

Rubber Fan

Shroud Seal

Angle

Bracket

Provided

Diagram #6

INSTALLATION

1.

Using a table or workbench, lay the Electric Fan Assembly on a flat surface, Electric Fan facing down.

2.

Take the supplied Rubber Fan Shroud Seal and install it onto the bottom edge of the Fan Shroud Assembly.

(See Diagram #4)

3.

Cut off any excess Rubber.

4.

Identify the four Angel Brackets, 1/4-20 x 3/4” Hex Bolts, 1/4” Flat Washers & 1/4-20 Lock Nuts.

5.

Attach the Angle Brackets to the Shroud using two bolts per bracket. (See Diagram #5)

Two 1/4” Flat Washers must be used between the Angled Brackets and the Shroud to avoid the rivet for full

Important:

adjustment range.

In some applications where the radiator flange is not right up against the fan shroud, longer bolts can be used to

Note:

space the Angle Brackets. (See Diagram #6) Hardware not included!

6.

Position the Electric Fan Assembly against the radiator in the desired location.

7.

Using the remaining 1/4-20 x 3/4” Hex Bolts, 1/4” Flat Washers & 1/4-20 Lock Nuts, attach the Electric Fan Shroud

Assembly to the radiator. (See Diagram #5)

In some cases the radiator flange may have to be drilled for proper alignment.

Note:

(Page 2)

Diagram #4

Fan Shroud
Assembly

Rubber Fan

Shroud Seal

1/4” Bolt

Radiator

Flange

1/4” flat
Washers

1/4” Nyloc Nut

Diagram #5

1/4” Flat Washer

Fan Shroud

Slotted

Holes

1/4-20 x 3/4”

Hex Bolts

WIRING

Important: The Electric Fan Assembly is built using a High Output two speed motor. If you choose to operate the fan using both
speeds, two switching devices must be used.

Reference Diagrams #7 & 8 on page 3

WIRING OPTIONS

There are a few options on how to activate (turn on) your new Electric Fan Assembly.

1.

Manual Switch - Install a switch in the passenger compartment and turn on Electric Fan as desired.

2.

Electric Fan Thermostat Switch

A.

Adjustable Thermostat - Allows an adjustment range for you to determine optimal turn on temperature.

B.

Pre Determined Temperature - Thermostat has a pre determined temp. from the factory that determines turn on temp.

We recommend using two thermostats therefore activating the low speed at an earlier temperature then the high speed.
Please visit www.derale.com for available thermostat options or visit your local retailer.

Important: When purchasing a thermostat always consider the maximum amp draw. Some thermostats are not designed to
properly handle higher amperage fans.

Note: When installing the Electric Fan with a Thermostat always follow manufacturer's instructions for specific details. In some
cases you will not need the supplied relay harness.

RELAY WIRE HARNESS MOUNTING

1.

Taking into consideration fan placement and wire routing requirements, choose a convenient location.
Avoid mounting near HOT engine components.

2.

Using the relay bracket as a template, mark and drill a 5/32” hole in the proper location.

3.

Using the #10 Sheet Metal Screws provided, install the relay/wire harness.

1/4” Flat Washer