Derale Performance 12" Tornado Electric Fan & 180 User Manual
Diagram #1, Diagram #3, Diagram #2
PRE INSTALLATION
PULLER APPLICATION
PUSHER APPLICATION
Note:
1.
Electric Fan is setup from the factory for Puller applications and requires no
modification.
2.
Check product label on Electric Fan shroud. The arrow on the label shows
airflow direction through the fan.
1.
Remove the nut/clip that holds fan blade to motor shaft.
2.
Remove fan blade from motor shaft.
This is an interference fit and
requires some effort. Be careful not to damage fan blade.
3.
Flip blade over and align groove in fan blade with roll pin on motor shaft.
4.
Reinstall nut/clip on motor shaft.
INSTALLATION INSTRUCTIONS
ELECTRIC FAN
PART # 16007, 16008, 16009 & 16012
16007-16008-16009-16012-InstructionSheet
Rev.2-08-2011
Dyno-Cool by Derale, Los Angeles, CA
800.421.6288 www.derale.com
Please read these instructions completely before beginning installation
PARTS LIST
QTY. DESCRIPTION
1
Electric Fan
4
Mounting Rods
4
Mounting Clips
4
Mounting Feet
5
1x1 Foam Pads
1
Thermostat Switch
1
Relay Wire Harness
1
7 Ft. 14 Ga. Wire
1
3/8” NPT Thread-in Probe
QTY. DESCRIPTION
1
Push-in Probe
1
Retaining Probe Clip
1
Blue 5/16” Ring Terminal
2
Blue #10 Ring Terminal
1
Blue Butt Connectors
2
Blue Wire Tap Connectors
4
4” Wire Ties
2
#10 Sheet Metal Screw
2
Blue Female Connectors
TOOLS NEEDED
12V Test Light
Wire Stripper
Crimping Tool
3/4” Wrench
Teflon Tape
Standard Screw Driver or
a 5/16” Nut Driver
Drill
5/32” Drill Bit
Dyke Pliers
IMPORTANT
This fan assembly is designed
for both PULLER and
PUSHER APPLICATIONS.
(See Diagram #1)
Puller Fan
Pusher Fan
Air Flow
Engine Radiator
Diagram #1
Mounting
Rods
Mounting
Clips
Foam
Pads
Diagram #3
ELECTRIC FAN MOUNTING
1.
Position the electric fan against the radiator in the desired location.
2.
Take the Plastic Rods provided and install through the four mounting holes on the shroud pushing them slowly into and
through the radiator core. (See Diagram #2)
Do not use excessive force when pushing Plastic Rods through radiator core. Excessive force could cause
damage to the radiator fins and/or core. Plastic Rods should not be inserted thru both the radiator and the condenser cores.
3.
Take the 1 x 1 Foam pads provided and install them onto the Plastic Rods now protruding through the radiator core. (See
Diagram #3)
4.
Take the Plastic Clips provided, making sure they are in the correct direction (Derale writing out) install onto the Plastic
Rods and cinch them until the 1 x 1 Foam Pads are compressed. (See Diagram #3)
5.
Cut off the excess Plastic Rod.
Caution:
(Continues on Page 2)
Diagram #2
Mounting
Feet