Fault code

Possible cause

Checking

F 57
Thermistor fault

Thermistor input in relay / thermistor
board has detected motor
overtemperature. Fault appears when
thermistor input has been open over 1s.

Check:
− motor cooling and loading

− thermistor connection. If expansion board

thermistor input is not used, it should be
shorted

− motor parameters

− the brake operation

F 60
Parameter fault

Inverter has lost parameters. Drive
selection parameter has changed to 0 /
none.

Download parameters from keypad

F 61
Overspeed Fault

SSU has tripped to Overspeed
(hardware supervision). Motor speed
has increased above overspeed
detection level.

Reset when 1s without pulses from pulse
sensor/encoder to SSU and controller at zero
position.
Check:
− function and cabling

− maximum frequency setting parameters

− SSU settings

F 62
Speed Difference
Fault

SSU has tripped to Speed Difference

Reset when 1s without pulses from pulse
sensor/encoder to SSU and controller at zero
position.
Check:
− pulse sensor/encoder function and cabling

− pulse sensor/encoder pulse number

− speed difference supervision settings

F 63
Stall Supervision
Fault

SSU has tripped to Stall

Reset when 1s without pulses from pulse
sensor/encoder to SSU and controller at zero
position.
Check:
− brake operation

− pulse sensor/encoder function and cabling

− stall supervision settings

F 64
SSU Relay Test Fault

Relay in SSU board is damaged, SSU
relay is bypassed or OK input is
damaged.

Reset: switch power off and restart after the lamps
of keypad are off.
Check:
− ES and RDY external connections

− OK input operation

− change SSU board

F 65
SSU Watchdog

SSU internal fault
− interference fault between SSU

board and control board

− component failure (control board or

SSU board)

Check:
− SSU status (System menu / System info /

Expander boards / C: SSU / status)

− SSU LED’s
If the fault comes again, contact authorized
service

F 66
SSU Overspeed Limit

SSU overspeed limit has been set over
140% of maximum frequency

Check:
− set SSU overspeed limit under 140% of

maximum frequency

− motor type plate parameters

− maximum frequency parameters

F 70
Multicare Fault

Other D2H/D2C has tripped to fault or
brake of other D2H/D2C has not been
opened. Fault is not stored into fault
history.

Check other D2H/D2C:
− fault history

− brake operation

− brake relay control delay settings

F 71
Brake Control Fault

Load information from load measuring
device is out of operation window

Check
− Ain2 wiring

− settings of load measuring device

F 72
Brake Feedback Fault

Brake is opening or closing in wrong
time

Check:
− brake operation

− brake relay (ROB2) and brake contactor

(K7/K71) operation