Installation to Extension Column

Screw extension column (EXT or ADJ
Series
) to ceiling plate (B). Align the notch
with one of the four holes in the ceiling plate
and secure extension column with a M5 x 10
mm socket pin screw (P) using security allen
wrench (G). See fi gure 3-5.
Note: Slotted set screw (N) is used to
jam against the threads of the reducer
to prevent any excess movement of the
extension column. Do not overtighten screw;
overtightening screw will damage threads
making it diffi cult to separate the products.

Screw extension column connector
(ACC 109) to extension column. Align slot in
extension column with one of the top holes
in extension column connector. Insert and
tighten one #10-32 x 3/8" socket pin screw
provided with projector through extension
column connector into slot on extension
column using security allen wrench (G). See
fi gure 3-6.

Screw reducer (D) to extension column
connector. Align reducer to one of the
bottom holes in extension column connector.
Insert and tighten one #10-32 x 3/8" socket
pin screw provided with connector through
extension column connector into slot in
reducer using security allen wrench (G). See
fi gure 3-7.

Note: Slotted set screws provided with
extension column connector are used to jam
against the threads of each connecting joint
to prevent any excess movement. Do not
overtighten screws; overtightening screws
will damage threads making it diffi cult to
separate the products.

Skip to step 4.

B

SLOT

SLOT

SLOT

B

SLOT

fi gure 3-5

P

B

D

N

fi gure 3-6

fi gure 3-7

EXTENSION
COLUMN
CONNECTOR
(SOLD SEPA-
RATELY)

SOCKET PIN
SCREW

SOCKET PIN
SCREW

EXTENSION
COLUMN
(UL Listed EXT
or ADJ Series)
Sold Separately

EXTENSION
COLUMN

EXTENSION
COLUMN

SET SCREW

SET SCREW

EXTENSION
COLUMN

ACC 109

ACC 850 - EXTENSION COLUMN

CONNECTOR WITH CORD MANAGEMENT

- MAY BE USED IN PLACE OF EXTENSION

COLUMN CONNECTOR. (SOLD

SEPARATELY)

ACC 109