Installation to Concrete Ceilings

Drill two 5/16" (8 mm) dia. holes to a minimum depth
of 2.5" (64 mm). Attach ceiling plate (B) using two
concrete anchors (H) and #14 x 2.5" wood screws (E)
as shown in Illustration A and 1, 2, and 3 (below).
Tighten all fasteners.

E

B

H

Illustration A

CONCRETE CEILING

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware

and components.

WARNING

• Tighten screws so that wall plate is fi rmly attached,

but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-be aring concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other
fi nishing material. If mounting to concrete surfaces
covered with a fi nishing surface is unavoidable,
the fi nishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws.
If plaster/drywall is thicker than 5/8" (16 mm),
custom fasteners must be supplied by installer (not
evaluated by UL).

WARNING

CUT

A

W

A

Y

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/
dry wall

plaster/
dry wall

concrete

concrete

1

3

2

H

Drill holes and insert anchors (H).

Place plate (B) over anchors (H) and secure with screws (E).