I-7565-H1/H2 High Speed USB/CAN Converter Quick Start User Guide (Ver 1.0, Sep/2009) 3

3. Test I-7565-H1 by using I-7565-H1/H2 Utility

Step1: Set the Init / Normal switches on the back of the I-7565-H1 A and

B to the “

Normal

” position. Then, turn on the DC power. The PWR

LED of the I-7565-H1 A and B will be always turned on. It means
these two I-7565-H1 converters are working in the “Firmware
Operation” mode.

Step2:

Run the “I-7565-H1/H2 Utility”, I-7565-H1H2_Utility.exe, and
configure the connection parameters and then click “Connect”
button to connect to the I-7565-H1 A module like Figure 3-1.

Port No

: The Virtual COM Port Number (Port3 => Figure 3-2)

Mod Name

: The Module Name (I-7565-H1)

Port Enable

: Port 1 checked

Baud Rate

: 1000K bps

.

Figure 3-1

: Connection Screen of I-7565-H1/H2 Utility

Figure 3-2

: The Virtual COM Port Number