• Fault Loopback
The IE-iMcV-T1/E1/J1-LineTerm, TP/SFP with SFP Host unit can also display the
DDMI information from the Remote LineTerm module. Please download the
latest SNMP Management Module firmware and iVIew² software to ensure the
full support and functionality of the modules.

NOTE

IE-iMcV-T1/E1/J1-LineTerm, TP/SFP

with SFP Module can be installed in an

iMediaChassis and MediaChassis series.

Installing an iMcV-Module

iMcV-Modules install in B&B Electronics’ SNMP manageable iMediaChassis series
or in any MediaChassis/IE-MediaChassis series.

To install an iMcV-Module:
1. Remove the blank bracket covering the slot where the module is to be

installed by removing the screws on the outside edges of the bracket.

2. Slide the iMcV-Module into the chassis, via the cardguides, until the module

is seated securely in the connector.

3. Secure the module to the chassis by tightening the captive screw.
4. Save any “blanks” removed during installation for future use if the

configuration requirements change.

NOTE

All modules are hot-swappable

Crossover/Straight-Through Connection

IE-iMcV-T1/E1/J1-LineTerm, TP/SFP comes with an RJ-48 UTP connector that
features a push-button switch, located next to the port, for selecting a crossover
connection, push-button IN. A straight-through connection is selected when the
push-button is OUT. When unsure what type of connection is needed, set the
push button to the position that turns the LOS LED off.

Configuration

Proper configuration of the IE-iMcV-T1/E1/J1-LineTerm, TP/SFP is required for
maximum performance and reliability. The following sections describe the
prerequisites and the configurations available for both managed and unmanaged
modules.