N-Link – Configuration, Continued…

Complex N-Link Configuration (Example):

N-Ring #1

N-Ring AM

N-Link Slave

#1

N-Ring AM

N-Link Master

#1

Partner
Link #1

Control
Link #1

N-Rng

Manager

N-Link AC

N-Ring AM

N-Link AC

N-Ring AM

N-Ring

Auto

Member

Primary
Coupler

Link #1

Standby

Coupler

Link #1

N-Ring #2

N-Ring

Auto

Member

N-Ring AM

N-Link Slave

#2

N-Ring AM

N-Link Master

#2

Partner
Link #2

Control
Link #2

N-Rng

Manager

N-Link AC

N-Ring AM

N-Link AC

N-Ring AM

N-Ring

Auto

Member

Primary
Coupler

Link #2

Standby

Coupler

Link #2

N-Ring #3

N-Ring

Auto

Member

N-Ring AM

N-Link Slave

#3

N-Ring AM

N-Link Master

#3

Partner

Link#3

Control
Link #3

N-Rng

Manager

N-Link AC

N-Ring AM

N-Link AC

N-Ring AM

N-Ring

Auto

Member

Primary
Coupler

Link #3

Standby

Coupler

Link #3

N-Ring #4

N-Ring

Auto

Member

N-Ring

Auto

Member

N-Ring

Auto

Member

N-Rng

Manager

• The Master and Slave must be part of the N-Ring topology.

Configuration Notes:

• If using default configuration choices, the administrator only needs to configure the N-Link Master.

The N-Link Slave and both Coupler switches will auto-detect any needed configuration.

• If not using default configuration choices, the administrator may also need to configure the Default

Coupler port on the N-Link Slave.

• There must be a direct link between the Master and Slave Control ports. Use of media converters or

other switches is not supported.

• There must be a direct link between the Master and Slave Partner ports. Use of media converters or

other switches is not supported.

• There must be at least one other switch, besides the Master and Slave, that supports N-Link on the

N-Ring.

• N-Link will only support a single point of failure. Multiple points of failure and misconfiguration

are not supported and may cause a network storm under some circumstances.

1. Ensure the Coupler and Control cables are disconnected at this point.

Configuration Steps to redundantly couple 2 N-Ring networks:

2. Get Both N-Rings working with a status of OK.
3. Configure N-Link Slave: Ensure that the N-Link Slave is set to Auto Configure and select a Default

Coupler Port. Save Configuration.

4. Configure N-Link Master: Select the Control and Coupler ports. Save the Configuration.
5. Connect the Control Link cable. Ensure that the Slave switch status now shows a state of “Slave”
6. Connect the Coupler Link cables.
7. Check N-Link status by selecting the N-Link Status View page.