Communication speed, Example for the modectrl register – Rainbow Electronics AT77C105A User Manual
Page 25

25
AT77C105A [Preliminary]
5419A–BIOM–01/05
Communication Speed
To reduce consumption, the control interface’s communication speed is set to the lowest
possible speed and depends on the host’s configuration.
To communicate with “fast” controllers, the sensor’s communication speed can be set to
200 kbits/s.
Example for the MODECTRL
Register
Figure 10 represents a typical writing sequence into an internal register (MODECTRL
register in this example).
See Appendix B for flowchart.
Figure 10. Writing into an Internal Register
Note:
The break on SCK on the SPI chronogram has been added for better comprehension only. In a real application, SCK can be
continuous.
Figure 11 represents a typical reading sequence of a register different from the naviga-
tion register. In this example, the status register is used.
Figure 11. Reading Sequence of a Register (Except for Navigation Registers)