Enctrl register, Heatctrl register – Rainbow Electronics AT77C105A User Manual
Page 16

16
AT77C105A [Preliminary]
5419A–BIOM–01/05
Enctrl Register
Register Name: Enctrl (7 bits)
Access Type: Read/Write
Function: Interrupts control
•
CLICKEN: Click interrupts enable
0: default
1: click IRQ enabled
IRQ is generated when a click is detected.
•
MOVEN: Movement interrupts enable
0: default
1: movement IRQ enabled
IRQ is generated when an X or Y movement is detected.
•
TRANSITEN: Not used, for testing only
•
SLICEN: Not used, for testing only
•
READERREN: Read error interrupts enable
0: default
1: read error IRQ enabled
IRQ is generated when a read error is detected.
Note:
The interrupt is cleared after the status register is read.
Heatctrl Register
Register Name: Heatctrl (7 bits)
Access Type: Read/Write
Function: Heating control
•
HEAT: Sensor heating
0: default, no heating
1: heating
The default value is recommended to optimize power consumption.
•
WDOGEN: Watchdog enable
0: default
b6
b5
b4
b3
b2
b1
b0
CLICKEN
MOVEN
TRANSITEN
SLICEN
READERREN
–
–
0
0
0
0
0
0
0
b6
b5
b4
b3
b2
b1
b0
HEAT
WDOGEN
HEATV (MSB)
HEATV(LSB)
–
–
–
0
0
0
0
0
0
0