Electrical characteristics (continued) – Rainbow Electronics ATA6631 User Manual
Page 20
20
9165A–AUTO–11/09
ATA6629/ATA6631
8.8
LIN current limitation
V
BUS
= V
Batt_max
LIN
I
BUS_LIM
40
120
200
mA
A
8.9
Input leakage current at
the receiver including
pull-up resistor as
specified
Input Leakage current
Driver off
V
BUS
= 0V
V
Batt
= 12V
LIN
I
BUS_PAS_dom
–1
–0.35
mA
A
8.10
Leakage current LIN
recessive
Driver off
8V < V
Batt
< 18V
8V < V
BUS
< 18V
V
BUS
≥
V
Batt
LIN
I
BUS_PAS_rec
10
20
µA
A
8.11
Leakage current when
control unit disconnected
from ground.
Loss of local ground
must not affect
communication in the
residual network
GND
Device
= V
S
V
Batt
= 12V
0V < V
BUS
< 18V
LIN
I
BUS_NO_gnd
–10
+0.5
+10
µA
A
8.12
Leakage current at
disconnected battery.
Node has to sustain the
current that can flow
under this condition. Bus
must remain operational
under this condition.
V
Batt
disconnected
V
SUP_Device
= GND
0V < V
BUS
< 18V
LIN
I
BUS_NO_bat
0.1
2
µA
A
9
LIN Bus Receiver
9.1
Center of receiver
threshold
V
BUS_CNT
=
(V
th_dom
+ V
th
_
rec
)/2
LIN
V
BUS_CNT
0.475
×
V
S
0.5
×
V
S
0.525
×
V
S
V
A
9.2
Receiver dominant state V
EN
= 5V
LIN
V
BUSdom
–27
0.4
×
V
S
V
A
9.3
Receiver recessive state V
EN
= 5V
LIN
V
BUSrec
0.6
×
V
S
40
V
A
9.4
Receiver input hysteresis V
hys
= V
th_rec
– V
th_dom
LIN
V
BUShys
0.028
×
V
S
0.1 x V
S
0.175
×
V
S
V
A
9.5
Pre-wake detection LIN
High level input voltage
LIN
V
LINH
V
S
– 2V
V
S
+
0.3V
V
A
9.6
Pre-wake detection LIN
Low level input voltage
Activates the LIN receiver
LIN
V
LINL
–27
V
S
– 3.3V
V
A
10
Internal Timers
10.1
Dominant time for
wake–up via LIN bus
V
LIN
= 0V
LIN
t
bus
30
90
150
µs
A
10.2
Time delay for mode
change from Fail-safe
into Normal Mode via pin
EN
V
EN
= 5V
EN
t
norm
5
15
20
µs
A
10.3
Time delay for mode
change from Normal
Mode to Sleep Mode via
pin EN
V
EN
= 0V
EN
t
sleep
2
7
15
µs
A
9.
Electrical Characteristics (Continued)
5V < V
S
< 27V, –40°C < T
j
< 150°C; unless otherwise specified all values refer to GND pins.
No.
Parameters
Test Conditions
Pin
Symbol
Min.
Typ.
Max.
Unit
Type*
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter