Pin description – Rainbow Electronics MAX9860 User Manual
Page 13
MAX9860
16-Bit Mono Audio Voice Codec
______________________________________________________________________________________
13
Pin Description
PIN
NAME
FUNCTION
1
MICBIAS
Microphone Bias. +1.55V microphone bias for internal and/or external microphone. An external resistor from
2.2k
Ω to 470Ω should be used to set the microphone current. Bypass to MICGND with a 1µF capacitor.
2
REG
Internal Bias. PREG/2 voltage reference. Bypass to AGND with a 1µF capacitor (+0.8V).
3
PREG
Positive Internal Regulated Supply. Bypass to AGND with a 1µF capacitor (+1.6V).
4
REF
Converter Reference (1.23V). Bypass to AGND with a 2.2µF capacitor.
5
AGND
Analog Ground
6
AVDD
Analog Power Supply. Bypass to AGND with 10µF and 0.1µF capacitors.
7
OUTP
Positive Headphone Output
8
OUTN
Negative Headphone Output
9
SDA
I
2
C Serial-Data Input/Output
10
SCL
I
2
C Serial-Data Clock
11
DVDDIO
Digital Interface Power Supply. Supply for digital audio interface. Bypass to DGND with a 1µF capacitor.
12
DGND
Digital Ground
13
DVDD
Digital Core Power Supply. Bypass to DGND with a 1µF capacitor.
14
MCLK
Master Clock Input
15
SDOUT
Serial Audio Interface ADC Data Output
16
SDIN
Serial Audio Interface DAC Data Input
17
LRCLK
Serial Audio Interface Left/Right Clock
18
BCLK
Serial Audio Interface Bit Clock
19
IRQ
Interrupt Request. IRQ is an active-low open drain output. Pull up to DVDDIO with a 10k
Ω resistor.
20
MICRN
Negative Right Microphone Input. AC-couple to low-side of microphone or connect to negative signal.
AC-couple to ground for single-ended operation.
21
MICRP
Positive Right Microphone Input. AC-couple to high-side of microphone or connect to positive signal.
AC-couple the signal for single-ended operation.
22
MICLN
Negative Left Microphone Input. AC-couple to low-side of microphone or connect to negative signal.
AC-couple to ground for single-ended operation.
23
MICLP
Positive Left Microphone Input. AC-couple to high-side of microphone or connect to positive signal.
AC-couple the signal for single-ended operation.
24
MICGND
MICBIAS Ground. Connect to AGND.
—
EP
Exposed Pad. Connect to AGND.