Dc electrical characteristics (continued) – Rainbow Electronics MAX34440 User Manual
Page 7
PMBus 6-Channel Power-Supply Manager
MAX34440
7
DC ELECTRICAL CHARACTERISTICS (continued)
(V
DD
= 2.7V to 5.5V, T
A
= -40NC to +85NC, unless otherwise noted. Typical values are at V
DD
= 3.3V, T
A
= +25NC, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
ADC Internal Reference Initial
Accuracy (+25NC)
-1
+1
mV
ADC Full-Scale Input Voltage
V
FS
1.213
1.225
1.237
V
ADC Measurement Resolution
V
LSB
300
F
V
ADC Bit Resolution
12
Bits
RS+ Input Resistance
R
IN
15
MI
ADC Integral Nonlinearity
INL
Q
4
LSB
ADC Differential Nonlinearity
DNL
Q
1
LSB
ADC Offset
V
OFFSET
Q
2
LSB
Internal Temperature
Measurement Error
T
A
= -40NC to +85NC
-3
+3
N
C
Store Default All Time
37
ms
Nonvolatile Log Write Time
12
ms
Nonvolatile Log Delete Time
200
ms
Flash Endurance
N
FLASH
T
A
= +50NC
20,000
Write
Cycles
Data Retention
T
A
= +50NC
100
Years
Voltage Sample Rate
5
ms
Current Sample Rate
200
ms
Temperature Sample Rate
1000
ms
Device Startup Time
Measurement from POR until monitoring
begins
12
ms
PWM Frequency
Power supply
62.5
kHz
PWM Resolution
Power supply
6
Bits