2 weight, 3 environmental requirements, 1 temperature range – Rainbow Electronics UC864 User Manual
Page 10: 2 vibration test (non functional)

UC864-E/G Product Description
80281ST10034a Rev. 1
- 08/08/2008
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 10 of 36
2.2 Weight
Weight
UC684-E
10 gr.
UC864-G
12.8 gr.
2.3 Environmental requirements
The
Telit UC864-E/G
module is compliant with the applicable 3gpp reference documentation TS
25.101 Release 2004-03.
2.3.1
Temperature range
UC864-E/G
Note
Operating temperature
-20 ~ +55°C
The module is functional in all
the temperature range, and it fully
meets the
ETSI specifications.
-30 ~ +80°C
The module is functional in all
the temperature range. Temperatures
outside the range –20°C ÷ +55°C,
might slightly deviate from ETSI specifications.
Temperature in not
functional conditions
-40 ~ +85°C
* Functional: the module is able to make and receive voice calls, data calls, SMS and make data traffic..
2.3.2
Vibration Test (non functional)
•
10 ~12Hz ASD = 1.92m 2 /s 3
•
12 ~ 150Hz –3dB/oct