Mfr_fan_lut (f2h), Temperature step: temperature level setting, Table 33. mfr_fan_lut – Rainbow Electronics MAX34441 User Manual
Page 48: Table 34. valid temperature range
![background image](/manuals/280508/48/background.png)
PMBus 5-Channel Power-Supply Manager
and Intelligent Fan Controller
MAX34441
48
MFR_FAN_LUT (F2h)
The MFR_FAN_LUT command is used to configure the LUT that controls the fan. The fan has an LUT that maps eight
programmable temperature levels to eight programmable fan PWM duty-cycle levels (bit 6 in FAN_CONFIG_1_2 is
zero) or eight programmable target fan speeds (bit 6 in FAN_CONFIG_1_2 is one). The LUT allows a wide variety of
profiles to be used.
USER NOTE: The programmable configuration of MFR_FAN_LUT must be monotonic.
Table 33. MFR_FAN_LUT
TEMPERATURE STEP: Temperature Level Setting
The TEMPERATURE STEP sets the temperature in degrees Celsius and represents a threshold level at which the
device updates the fan PWM duty cycle setting. The 2 data bytes are in DIRECT format. The valid temperature range
depends on the temperature sensor.
Table 34. Valid Temperature Range
BYTE NUMBER
WORD NAME
MEANING
0-1
TEMP STEP 0
Temperature for step 0.
2-3
SPEED STEP 0
Fan PWM duty cycle or fan speed for step 0.
4-5
TEMP STEP 1
Temperature for step 1.
6-7
SPEED STEP 1
Fan PWM duty cycle or fan speed for step 1.
8-9
TEMP STEP 2
Temperature for step 2.
10-11
SPEED STEP 2
Fan PWM duty cycle or fan speed for step 2.
12-13
TEMP STEP 3
Temperature for step 3.
14-15
SPEED STEP 3
Fan PWM duty cycle or fan speed for step 3.
16-17
TEMP STEP 4
Temperature for step 4.
18-19
SPEED STEP 4
Fan PWM duty cycle or fan speed for step 4.
20-21
TEMP STEP 5
Temperature for step 5.
22-23
SPEED STEP 5
Fan PWM duty cycle or fan speed for step 5.
24-25
TEMP STEP 6
Temperature for step 6.
26-27
SPEED STEP 6
Fan PWM duty cycle or fan speed for step 6.
28-29
TEMP STEP 7
Temperature for step 7.
30-31
SPEED STEP 7
Fan PWM duty cycle or fan speed for step 7.
TEMPERATURE SENSOR
VALID RANGE
Page 6: Internal Temp Sensor
-40NC to +85NC
Pages 7 to 10: I
2
C Remote Temp Sensor
-55NC to +125NC
Page 11: Remote Thermal Diode Temp Sensor
-40NC to +120NC