STATUS_WORD (79h)
The STATUS_WORD command returns 2 bytes of information with a summary of the reason for a fault. The low byte of
the STATUS_WORD is the same data as the STATUS_BYTE. Table 21 describes the STATUS_WORD message content.
STATUS_VOUT (7Ah)
The STATUS_VOUT command returns 1 byte of information with contents as described in Table 22.
STATUS_CML (7Eh)
The STATUS_CML command returns 1 byte of information with contents as described in Table 23.
Table 21. STATUS_WORD
Table 23. STATUS_CML
Table 22. STATUS_VOUT
BIT
BIT NAME
MEANING
15
VOUT
An output voltage fault or warning or TON_MAX_FAULT has occurred.
14
IOUT
An overcurrent fault or warning has occurred.
13
0
This bit always returns a 0.
12
MFR
A bit in STATUS_MFR_SPECIFIC has been set.
11
POWER_GOOD#
A power-supply voltage has fallen from POWER_GOOD_ON to less than POWER_GOOD_OFF.
10
FANS
A fan fault has occurred.
9:6
0
These bits always return a 0.
5
VOUT_OV
An overvoltage fault has occurred.
4
IOUT_OC
An overcurrent fault has occurred.
3
0
This bit always returns a 0.
2
TEMPERATURE
A temperature fault or warning has occurred.
1
CML
A communication, memory, or logic fault has occurred.
0
NONE OF THE ABOVE A fault or warning not listed in bits [7:1] has occurred.
BIT
BIT NAME
MEANING
7
COMM_FAULT
An invalid or unsupported command has been received.
6
DATA_FAULT
An invalid or unsupported data has been received.
5:1
0
These bits always return a 0.
0
FAULT_LOG_FULL
MFR_NV_FAULT_LOG is full and needs to be cleared.
BIT
BIT NAME
MEANING
7
VOUT_OV_FAULT
VOUT overvoltage fault.
6
VOUT_OV_WARN
VOUT overvoltage warning.
5
VOUT_UV_WARN
VOUT undervoltage warning.
4
VOUT_UV_FAULT
VOUT undervoltage fault.
3
0
This bit always returns a 0.
2
TON_MAX_FAULT
TON maximum fault.
1:0
0
These bits always return a 0.