beautypg.com

external clock drive characteristics (xtal1), external clock drive waveforms, ac testing input/output waveforms – Rainbow Electronics T89C51RD2 User Manual

Page 84: float waveforms, External clock drive characteristics (xtal1), Float waveforms

background image

Rev. F - 15 February, 2001

84

T89C51RD2

9.5.11. External Clock Drive Characteristics (XTAL1)

Table 48. AC Parameters

9.5.12. External Clock Drive Waveforms

9.5.13. AC Testing Input/Output Waveforms

AC inputs during testing are driven at V

CC

- 0.5 for a logic “1” and 0.45V for a logic “0”. Timing measurement

are made at V

IH

min for a logic “1” and V

IL

max for a logic “0”.

9.5.14. Float Waveforms

For timing purposes as port pin is no longer floating when a 100 mV change from load voltage occurs and begins
to float when a 100 mV change from the loaded V

OH

/V

OL

level occurs. I

OL

/I

OH

≥ ±

20mA.

Symbol

Parameter

Min

Max

Units

T

CLCL

Oscillator Period

25

ns

T

CHCX

High Time

5

ns

T

CLCX

Low Time

5

ns

T

CLCH

Rise Time

5

ns

T

CHCL

Fall Time

5

ns

T

CHCX

/T

CLCX

Cyclic ratio in X2 mode

40

60

%

V

CC

-0.5V

0.45V

0.7V

CC

0.2V

CC

-0.1

T

CHCL

T

CLCX

T

CLCL

T

CLCH

T

CHCX

INPUT/OUTPUT

0.2 V

CC

+ 0.9

0.2 V

CC

- 0.1

V

CC

-0.5 V

0.45 V

FLOAT

V

OH

- 0.1 V

V

OL

+ 0.1 V

V

LOAD

V

LOAD

+ 0.1 V

V

LOAD

- 0.1 V