dc parameters for standard voltage (1), Dc parameters for standard voltage (1), 0 ° c to +70 ° c; v – Rainbow Electronics T89C51RD2 User Manual
Page 71: 0 v; v, 40 ° c to +85 ° c; v
71
Rev. F - 15 February, 2001
T89C51RD2
9.2. DC Parameters for Standard Voltage (1)
T
A
= 0
°
C to +70
°
C; V
SS
= 0 V; V
CC
= 5 V
±
10%; F = 0 to 40 MHz.
T
A
= -40
°
C to +85
°
C; V
SS
= 0 V; V
CC
= 5 V
±
10%; F = 0 to 40 MHz.
Table 35. DC Parameters in Standard Voltage (1)
Symbol
Parameter
Min
Typ
(5)
Max
Unit
Test Conditions
V
IL
Input Low Voltage
-0.5
0.2 V
CC
- 0.1
V
V
IH
Input High Voltage except XTAL1, RST
0.2 V
CC
+ 0.9
V
CC
+ 0.5
V
V
IH1
Input High Voltage, XTAL1, RST
0.7 V
CC
V
CC
+ 0.5
V
V
OL
Output Low Voltage, ports 1, 2, 3, 4 and 5
(6)
0.3
0.45
1.0
V
V
V
I
OL
= 100
µ
A
(4)
I
OL
= 1.6 mA
(4)
I
OL
= 3.5 mA
(4)
V
OL1
Output Low Voltage, port 0, ALE, PSEN
(6)
0.3
0.45
1.0
V
V
V
I
OL
= 200
µ
A
(4)
I
OL
= 3.2 mA
(4)
I
OL
= 7.0 mA
(4)
V
OH
Output High Voltage, ports 1, 2, 3, 4 and 5
V
CC
- 0.3
V
CC
- 0.7
V
CC
- 1.5
V
V
V
I
OH
= -10
µ
A
I
OH
= -30
µ
A
I
OH
= -60
µ
A
V
CC
= 5 V
±
10%
V
OH1
Output High Voltage, port 0, ALE, PSEN
V
CC
- 0.3
V
CC
- 0.7
V
CC
- 1.5
V
V
V
I
OH
= -200
µ
A
I
OH
= -3.2 mA
I
OH
= -7.0 mA
V
CC
= 5 V
±
10%
R
RST
RST Pulldown Resistor
50
90
200
k
Ω
I
IL
Logical 0 Input Current ports 1, 2, 3, 4 and 5
-50
µ
A
Vin = 0.45 V
I
LI
Input Leakage Current
±
10
µ
A
0.45 V < Vin < V
CC
I
TL
Logical 1 to 0 Transition Current, ports 1, 2, 3,
4 and 5
-650
µ
A
Vin = 2.0 V
C
IO
Capacitance of I/O Buffer
10
pF
Fc = 1 MHz
T
A
= 25
°
C
I
PD
Power Down Current
120
150
µ
A
V
CC
= 3 V to 5.5 V
(3)
I
CCOP
Power Supply Current onnormal mode
0.7 Freq
(MHz) + 3
mA
mA
V
CC
= 5.5 V
(1)
I
CCIDLE
Power Supply Current on idle mode
0.4 Freq
(MHz) + 2
mA
mA
V
CC
= 5.5 V
(2)