Figure 5. Auto-Reload Mode Up/Down Counter (DCEN = 1)

6.4.2. Programmable Clock-Output

In the clock-out mode, timer 2 operates as a 50%-duty-cycle, programmable clock generator (See Figure 6) . The
input clock increments TL2 at frequency F

OSC

/2. The timer repeatedly counts to overflow from a loaded value.

At overflow, the contents of RCAP2H and RCAP2L registers are loaded into TH2 and TL2. In this mode, timer
2 overflows do not generate interrupts. The formula gives the clock-out frequency as a function of the system
oscillator frequency and the value in the RCAP2H and RCAP2L registers :

For a 16 MHz system clock, timer 2 has a programmable frequency range of 61 Hz
(F

OSC

/2

16)

to 4 MHz (F

OSC

/4). The generated clock signal is brought out to T2 pin (P1.0).

Timer 2 is programmed for the clock-out mode as follows:

Set T2OE bit in T2MOD register.

Clear C/T2 bit in T2CON register.

Determine the 16-bit reload value from the formula and enter it in RCAP2H/RCAP2L registers.

Enter a 16-bit initial value in timer registers TH2/TL2. It can be the same as the reload value or a different
one depending on the application.

To start the timer, set TR2 run control bit in T2CON register.

(DOWN COUNTING RELOAD VALUE)

C/T2

TF2

TR2

T2

EXF2

TH2

(8-bit)

TL2

(8-bit)

RCAP2H

(8-bit)

RCAP2L

(8-bit)

FFh

(8-bit)

FFh

(8-bit)

TOGGLE

(UP COUNTING RELOAD VALUE)

TIMER 2

INTERRUPT

XTAL1

:

12

F

OSC

F

XTAL

0

1

T2CONreg

T2CONreg

T2CONreg

T2CONreg

T2EX:
if DCEN=1, 1=UP
if DCEN=1, 0=DOWN
if DCEN = 0, up counting

Clock

OutFrequency

F

osc

4

65536

RCAP2H

RCAP2L

(

)

Ч

--------------------------------------------------------------------------------------

=