Peerless Lighting TLWS - T5 User Manual
Tulip wall symmetric, Direct t5, Wall mount
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
TLWS D 1-T5
TLWS X 1-T5
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Direct T5
TLWS Tulip Wall Symmetric
Examples:
TLWS D 1 28T5 SSB 40FT R8 277 GEB10 SCT LP835 C100 — TLWS X 1 28T5 WPB 40FT R8 120 GEB10 1SE EC SCT LP835 C041
Wall Mount
TLWS
Tulip Wall Symmetric
Direct T5
__________
__________
__________
__________
__________
_________
__________
__________ __________
__________
Luminaire
TLWS
Mounting
Type
D Wall
spacer
X 21”
extended
arm mount
# of
Lamps in
Cross
Section
1
Lamp Type
28T5 28W T5
Shielding
SSB
Semi specular
baffle
WPB White painted
baffle
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R2
2’ individual unit
R3
3’ individual unit
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V
dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
______________
________________
________________
______________
_________________________________
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+
CRI Premier
LP835P 3500K 80+
CRI Premier
LP841P 4100K 80+
CRI Premier
Referenc
website or consult factory for
other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
DL
Damp location label
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire
sections. Separate feed required unless ELS or ELS2 is specified
Construction
Extruded aluminum housing forms a 3
5
⁄
8
” x 4”
curved channel. Die-cast aluminum end caps
mechanically attach with no exposed fasteners.
Extended arm mount (option “X”) is extruded
aluminum and die-cast aluminum, extending 21”.
Reflectors
High reflectance white painted reflector system.
Shielding
Arc-shaped, parabolic low iridescent semi-specular
or white painted aluminum louver.
Finish
Satin anodized or white low gloss paint. With satin
anodized option, housing is satin anodized and end
caps are painted to match. Custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wire s. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section. For total
luminaire length, add
3
⁄
8
” for each end cap. Using
internal joiners, 4’, 8’, and 12’ sections can be joined
to form longer length luminaires. Individual 2’ and 3’
luminaires also available.
TLWS D
TLWS X
3
5
⁄
8
”
7
⁄
16
”
4”
3
5
⁄
8
”
4”
21”