Peerless Lighting EGCW2 - T8 User Manual
Lightedge curved wall slots, Indirect t8, Wall mount
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightedge” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T8
EGCW2 Lightedge Curved Wall Slots
Examples:
EGCW2 1 32 48FT R12 120 GEB10 SCT LP835 C100
Wall Mount
EGCW2
Lightedge Curved
Wall Slots
Indirect T8
Construction
Housing and end caps are extruded aluminum
forming a 7
1
⁄
2
” x 2
1
⁄
4
” curvilinear profile.
Reflectors
Die-formed reflectors combine hammertone
specular aluminum and baked white enamel
(nominal reflectance 90%). Prismatic acrylic kicker
lens on 1 lamp product.
Shielding
Opal acrylic overlay above die-punched slot pattern
in aluminum housing.
Finish
Satin anodized standard. Custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’ and 12’ lengths in a single section. For total
luminaire length add 4” for each end cap. Using
internal joiners, 4’, 8’ and 12’ sections can be joined
to form longer-length luminaires. Individual 2’ and 3’
units also available, consult factory.
__________
__________
__________
_________
__________
__________ __________
__________
__________
Luminaire
EGCW2
# of Lamps in
Cross Section
1
Lamp Type
32
32W T8
Luminaire Row
Length
X FT
(4’ increments)
Maximum
Section Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1
Osram 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
______________
________________
______________
_________________________________
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired for energy
saving lamps.
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Referenc
consult factory for other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
EXT 3” extended mount (consult factory)
GLR Fusing (fast blow)
GMF Fusing (slow blow)
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
EGCW2 - 1
7
1
⁄
2
”
2
1
⁄