Peerless Lighting LL1M1 - T5_T5HO User Manual
Lightline, Indirect t5/t5ho, Suspended
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
T5HO Indirect
T8 Indirect
T5HO Indirect/Open
T5HO Lightvent
T8 Indirect/Open
T8 Lightvent
T8 Indirect/Direct with Baffle
T5HO Asymetric Wall Wash
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T5/T5HO
LL1M1 Lightline
Examples:
LL1M1 1 28T5 12FT R4 120 GEB10 SCT LP830 F1/12 C100 — LL1M1 1 54T5HO 24FT R12 120 GEB10 SCT LP841 F1/12 C041
Construction
Housing is extruded aluminum forming a
2
3
⁄
4
” x 2
1
⁄
2
” rectangular profile. Die-cast end plate
mechanically attaches with no exposed fasteners.
Reflectors
Die-formed, pre-finished white reflector with
hammertone specular aluminum.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Finish
Standard colors include satin anodized aluminum,
and white white (low gloss).
Luminaire Length
4’, 8’, and 12’ lengths in a single section for
suspension spacing of 4’, 8’, and 12’. For total
luminaire length, add
3
⁄
4
” for each end plate. Using
internal joiners, 4’, 8’, and 12’ sections can be joined
to form longer rows.
Suspended
LL1M1
Lightline
Indirect T5/T5HO
2
3
⁄
4
”
2
1
⁄
2
”
LL1M1
__________
__________
__________
_________
__________
__________ __________
__________
__________
Luminaire
LL1M1
# of
Lamps in
Cross
Section
1
Lamp Type
28T5
1
28W T5
54T5HO 54W T5HO
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
2
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1,2
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1,2
Osram 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
3
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
______________
________________
______________
______________
______________
_________________________________
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+
CRI Premier
LP835P 3500K 80+
CRI Premier
LP841P 4100K 80+
CRI Premier
Referenc
website or consult factory
for other options.
Mounting Type /
F1/
T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/
Hard ceiling (horizontal
J-box)
F3/
Rigid stem
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is
measured from ceiling to
bottom of luminaire.
Finish
C041 White white (low
gloss)
C100 Satin anodized
finish
C099 Custom finish
Options
ACG
Adjustable cable grippers
BLK
Black cord, cord manager and canopy (not available with F3)
CP
Chicago plenum (available with F1A only)
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2
Emergency through wiring w/single feed, separate neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
MCS
Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
OJB
Offset junction box
SLP
Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
XXXX Integrated sensor; choose options and obtain code on page 2
Notes:
1 Not available in 347V
2 Not available with 28T5 lamps
3 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified