beautypg.com

Peerless Lighting LLMS (Sus) - T5 User Manual

Lightline symmetric direct, Direct t5, Suspended

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Direct T5

LLMS  Lightline Symmetric

Examples:

LLMS 1 28T5 SSB 40FT R8 120 GEB10 SCT LP835 F1/18 C100

Suspended

LLMS

Lightline Symmetric

Direct

Direct T5

Construction

Extruded aluminum housing forms a 3

5

8

” x 4

1

16

rectangular profile. Die-cast aluminum end caps

mechanically attach with no exposed fasteners.

Shielding

Arc-shaped, parabolic low iridescent semi-specular

or white painted aluminum louver.

Reflectors

High reflectance white painted reflector system.

Finish

Satin anodized finish consists of satin anodized

housing with end caps painted to match. Custom

colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’ and 12’ lengths in a single section for exact

suspension spacing of 4’, 8’, and 12’. For total

luminaire length, add

7

8

” for each end cap. Using

internal joiners, 4’, 8’ and 12’ sections can be joined

to form longer rows.

__________

__________

__________

__________

_________

__________

__________ __________

__________

Luminaire

LLMS

# of Lamps in

Cross Section

1

Lamp Type

28T5 28W T5

Baffle

SSB

Semi specular

baffle

WPB White painted

baffle

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

DMHL3D

1

Lutron Hi-Lume dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

________________

________________

______________

______________

______________

_________________________________

Emergency Type

2

(Blank) None

EC

Emergency circuit

EL

1

Emergency

battery pack

EN

1

Emergency

battery pack

w/night light

circuit

Switching

SCT

Single circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

F3/

Rigid stem

Overall

Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall

suspension is

measured from

ceiling to bottom

of luminaire.

Finish

C041 White white (low

gloss)

C100 Satin anodized

finish

C099 Custom finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not

available with F3)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed,

shared neutral

ELS2

Emergency through wiring w/single feed,

separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified

with F2, ACG and OJB options)

XXXX Integrated sensor; choose options and obtain

code on page 2

Notes:

1 Not available in 347V

2 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

LLMS

3

5

8

4

1

16