Peerless Lighting LLWA - T8 User Manual
Lightline wall asymmetric direct, Direct t8, Wall mount
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Direct T8
Examples:
LLWA D 1 32 SSB 8FT R8 120 GEB10 1SE EC SCT LP830 C100 — LLWA X 1 32 WPB 8FT R8 120 GEB10 1SE EC SCT L/LP C041
Wall Mount
LLWA
Lightline Wall
Asymmetric Direct
Direct T8
Construction
Extruded aluminum housing forms a 3
5
⁄
8
” x 4
1
⁄
16
”
rectangular profile. Die-cast aluminum end caps
mechanically attach with no exposed fasteners.
Extended arm mount (Mounting Type “X”) is
extruded aluminum extending 21”.
Shielding
Arc-shaped, parabolic low iridescent semi-specular
or white painted aluminum louver.
Reflectors
High reflectance white painted reflector system.
Finish
Satin anodized finish consists of satin anodized
housing with end caps painted to match. Custom
colors available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section. For total
luminaire length, add
7
⁄
8
” for each end cap. Using
internal joiners, 4’, 8’, and 12’ sections can be joined
to form longer length luminaires.
__________
__________
__________
__________
_________
_________
__________
__________
__________
__________
Luminaire
LLWA
Mounting Type
D
Wall spacer
X 21”
extended
arm mount
# of Lamps in
Cross Section
1
Lamp Type
32
32W T8
Baffle
SSB Semi
specular
WPB White
baffle
Luminaire
Row Length
X FT
(4’ increments)
Maximum
Section Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
______________
________________
________________
______________
_________________________________
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired for energy
saving lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Referenc
consult factory for other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
DL
Damp location label
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
LLWA D
LLWA X
3
5
⁄
8
”
3
5
⁄
8
”
4
1
⁄
16
”
4
1
⁄
16
”
3
⁄
8
”
21”
LLWA Lightline Wall Asymmetric