LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

A

B

C

D

A

B

C

D

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “IceTray” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

ICW8  IceTray Wall Curved I/D

Examples:

ICW8 1 54T5HO OPD 40FT R12 277 GEB10 SCT LP835 C100 — ICW8 2 54T5HO OPD 32FT R8 277 GEB10 1SE EL DCT LP835 C041

Wall Mount

ICW8

IceTray Wall

Curved I/D

Indirect-Direct T5/T5HO

Construction

Housing is extruded aluminum with one-piece

aluminum baffle and a steel end cap.

Reflectors

Reflecting surfaces have white finish (nominal

90% reflectance).

Shielding

Straight blade baffles with perforated side reflector/

shield and opal acrylic diffuser overlay.

Finish

Satin anodized or white polyester powder paint.

Satin anodized finish consists of satin anodized

housing, clear-coated aluminum baffles and end

caps painted C110 to match. Note that clear-coated

aluminum baffles retain the slight imperfections

and characteristics of the raw aluminum source

material. Custom colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

Nominal 4’, 8’, and 12’ sections form row lengths.

For longer run lengths, sections are attached using

internal joiners. Add 1

3

8

” for each end cap to

determine total luminaire length. Using internal

joiners 4’, 8’, and 12’ fixtures can be joined to form

longer rows.

__________

__________

__________

__________

_________

__________

__________ __________

__________

Luminaire

ICW8

# of

Lamps in

Cross

Section

1

2

Lamp Type

28T5 28W T5

54T5HO 54W T5HO

Shielding

(Blank) No opal

OPD Standard brightness opal

overlay (recommended)

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

________________

________________

______________

_________________________________

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery pack

EN

1

Emergency battery pack

w/night light circuit

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed,

shared neutral

ELS2 Emergency through wiring w/single feed,

separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

NYC New York City code

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

ICW8 - 1

ICW8 - 2

6

5

8

3

1

8

6

5

8

3

1

8