beautypg.com

Peerless Lighting ENM4 - T5_T5HO User Manual

Envision i/d, Indirect-direct t5ho, Suspended

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Envision” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5HO

ENM4  Envision I/D

Examples:

ENM4 2 54T5HO 40FT R12 120 GEB10 2SE EL SCT LP835 F1/24 C041 — ENM4 1 54T5HO 12FT R8 277 GEB10 SCT L/LP F2/15 C100

Suspended

ENM4

Envision I/D

Indirect-Direct T5HO

Construction

Housing is extruded aluminum forming a 8” x 3”

curved profile. Die-cast end plate attaches with no

exposed fasteners.

Shielding

Parabolic aluminum baffles semi-specular finish.

Includes VisorOptic opal diffuser lamp shield.

Reflectors

Die-formed pre-painted white steel, hammertone

specular aluminum and specular aluminum.

Finish

Satin anodized or white paint standard. Custom

colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’

1

4

”, 8’, and 12’ lengths in a single section for

exact suspension spacing of 4’, 8’, and 12’. For total

luminaire length add

1

2

” for each end cap. Using

internal joiners, 4’, 8’, and 12’ sections can be joined

to form longer-length luminaires.

________

________

________

________

________

________

________

________________________

______________

______________

Luminaire

ENM4

# of

Lamps in

Cross

Section

1

2

Lamp Type

54T5HO 54W T5HO

Baffle

SSB Semi-

specular

baffle

WPB White

painted

baffle

Nominal

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

ADZT

1

Advance Mark 7 0-10V

dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

2

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery

pack

EN

1

Emergency battery

pack w/night light

circuit

________

________________

______________

______________

______________

_________________________________

Switching

SCT Single

circuit

DCT Dual

circuit

Lamp Color

L/LP No lamp

LP830 3000K 80+ CRI

LP835 3500K 80+ CRI

LP841 4100K 80+ CRI
Reference

Lamp Chart

on

website or consult factory for

other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

Overall

Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall suspension

is measured from

ceiling to bottom

of luminaire.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy

CP

Chicago plenum (available with F1A mtg only)

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2

Emergency through wiring w/single feed, separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified with F2, ACG and

OJB options)

XXXX Integrated sensor; choose options and obtain code on page 2

Notes:

1 Not available in 347V

2 Emergency type is installed in last 4’ of luminaire sections. Separate feed required unless

ELS or ELS2 is specified. EL and EN not available with DCT option in 4’ individual luminaires.

8”

8”

2

9

16

ENM4 - 2

ENM4 - 1

2

9

16