beautypg.com

Peerless Lighting IRDW8 - T5_T5HO User Manual

Icetray rectangular wall direct, Direct t5/t5ho, Wall mount

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “IceTray” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Direct T5/T5HO

IRDW8  IceTray Rectangular Wall Direct

IceTray Rectangular

Wall Direct

Direct T5/T5HO

Examples:

IRDW8 1 54T5HO OPI 40FT R12 277 GEB10 SCT LP835 C100 — IRDW8 1 54T5HO OPI 32FT R8 277 GEB10 1SE EL SCT LP835 C041

Wall Mount

IRDW8

Construction

Nominal 4” x 6” with extruded aluminum spine

and nominal four 4’ one-piece aluminum baffle

assemblies. Steel and die-cast aluminum sculptured

end cap.

Reflectors

White painted center reflector (nominal 90%

reflectance).

Shielding

Straight blade baffles with intermediate brightness

opal acrylic diffuser overlay.

Finish

Satin anodized or white polyester powder paint.

Satin anodized finish consists of satin anodized

housing, clear-coated aluminum baffles and end

caps painted C110 to match. Note that clear coated

aluminum baffles retain the slight imperfections

and characteristics of the raw aluminum source

material. Custom colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’, and 12’ lengths in a single section for exact

suspension spacing of 4’, 8’ and 12’. For total

luminaire length, add 1

3

8

” for each end cap. Using

internal joiners 4’, 8’, and 12’ sections can be joined

to form longer rows. Individual 2’ and 3’ units also

available, consult factory

__________

__________

__________

__________

_________

__________

__________ __________

__________

Luminaire

IRDW8

# of

Lamps in

Cross

Section

1

Lamp Type

28T5 28W T5

54T5HO 54W T5HO

Shielding

OPI

Intermediate brightness

opal diffuser

OPD Standard brightness opal

diffuser

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

________________

________________

______________

_________________________________

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery

pack

EN

1

Emergency battery

pack

w/night light circuit

Switching

SCT

Single circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

DL

Damp location label

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

NYC New York City code

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

IRDW8 - 1

Wall Mount

3

13

16

3

8

6

3

8