Peerless Lighting NRW9 - T8 User Manual
Naro wall, Wall mount, Nrw9
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
T8
NRW9 Naro Wall
Wall Mount
NRW9
Naro Wall
T8
5
1
⁄
4
”
5
1
⁄
4
”
3
⁄
8
”
3
⁄
8
”
2
3
⁄
4
”
2
3
⁄
4
”
NRW9 - 1
NRW9 - 2
Examples:
NRW9 1 32 WHR FST 40FT R8 277 GEB10 SCT LP835 C100 — NRW9 2 32 WHR FST 40FT R8 277 GEB10 1SE EL SCT LP835 C100
Construction
Nominal 5
1
⁄
4
”W x 2
3
⁄
4
”H extruded aluminum
housing. Die-cast aluminum end caps are
mechanically attached with no exposed fasteners.
Reflectors
Die-formed white painted steel.
Shielding
Frosted acrylic diffuser.
Finish
White polyester powder painted or satin anodized.
Satin anodized finish consists of satin anodized
housing with end caps painted C110 (aluminum)
to match. Optional custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section. For total
luminaire length add
1
⁄
2
” for each standard end cap.
Using internal joiners, 4’, 8’ and 12’ sections can be
joined to form longer rows.
Eco-friendly Packaging
100% post-consumer recycled cardboard box,
100% recycled cardboard cradles and kraft paper
tape. Biodegradable, protective luminaire bag.
__________
__________
__________
__________
__________
_________
__________
__________ __________
__________
Luminaire
NRW9
# of
Lamps in
Cross
Section
1
2
Lamp Type
32 T8
Reflector
WHR White
Reflector
Shielding
FST Frosted
Diffuser
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
2
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
______________
________________
________________
______________
_________________________________
Emergency Type
2
(Blank) None
EC Emergency
circuit
EL
1
Emergency
battery pack
EN
1
Emergency
battery pack
w/night light
circuit
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy saving
lamps.
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Referenc
website or consult factory
for other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate
neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified