Peerless Lighting 10CRM4 - T8 User Manual
Cerra 10 i/d, Indirect-direct t8, Suspended
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
________ _______
________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ _____
________ ________ _____________________
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect-Direct T8
10CRM4 Cerra 10 I/D
Examples:
10CRM4 2 32 WHR SSB 40FT R12 277 GEB10 DCT LP835 F1/18 C210 SCEP — 10CRM4 3 32 20/80 PPL 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110
Cerra 10 I/D
Indirect-Direct T8
Suspended
10CRM4
SCEP Option
10CRM4 - 1
2
5
⁄
8
”
10”
10CRM4 - 2
2
5
⁄
8
”
10”
10CRM4 - 3
2
5
⁄
8
”
10”
Construction
Nominal 10” x 3” crescent housing is formed from
one-piece cold-rolled steel. Flat end plate standard.
Sculptured die-cast aluminum end cap is optional.
Reflectors
Die-formed highly reflective white or specular
reflector.
Shielding
SSB—Parabolic aluminum baffle with semi specular
finish. SBL—Steel straight blade baffle.
PPL—Perforated steel straight blade baffle.
WPB—Parabolic aluminum baffle with white finish.
Finish
Fine-textured, white or aluminum polyester
powder paint. Custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section for nominal
suspension spacing of 4’, 8’, and 12’. For total
luminaire length, add
1
⁄
16
” for each flat end plate
or 4” for each sculptured end cap. Using internal
joiners, 4’, 8’, and 12’ sections can be joined to form
longer length luminaires.
_______
________
_______
__________
__________
_________
_________
__________
_________ __________
Luminaire
10CRM4
# of
Lamps
in
Cross
Section
1
2
3
Lamp Type
32
32W T8
Distribution
1
WHR White Reflector
(Standard)
SPR Specular
40/60 40% Up, 60% Down
20/80 20% Up, 80% Down
0/100 0% Up, 100% Down
CLI
2
Center Lamp Isolator
Shielding
(Blank) No
diffuser
OPD Standard
Brightness
Diffuser
Baffle
SSB
Semi specular
SBL
White steel
blade
PPL White
perforated
steel baffle
WPB White Baffle
(pre-finished
or painted)
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10 <10% THD Electronic
ADEZ
3
Advance Mark 10 dim
DMHL3D
3
Lutron Hi-Lume dim
ADZT
3
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
__________
________________
_________
________________
______________
______________
______________
_________________________________
# of
Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency
Type
4
(Blank) None
EC Emergency
circuit
EL
3
Emergency
battery pack
EN
3
Emergency
battery pack
w/night light
circuit
Switching
SCT Single
circuit
DCT Dual
circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy saving
lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Reference
website or consult factory
for other options.
Mounting Type /
F1/
T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/
Hard ceiling (horizontal
J-box)
F3/
Rigid stem
Overall
Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall
suspension is
measured from
ceiling to bottom
of luminaire.
Finish
C110 Painted
aluminum (low
gloss)
C210 White white
(fine-textured
low gloss)
C099 Custom finish
Options
ACG
Adjustable cable grippers
BLK
Black cord, cord manager and canopy (not
available with F3)
CP
Chicago plenum (available with F1A only)
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed,
shared neutral
ELS2
Emergency through wiring w/single feed,
separate neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
MCS
Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC
New York City code
OJB
Offset junction box
SCEP
Sculptured end cap
SLP
Sloped ceiling (for 10-45°, must be specified
with F2, ACG and OJB options)
XXXX Integrated sensor; choose options and obtain
code on page 2
Notes:
1 Refer to photometric test for exact distribution
2 Available with 3-lamp cross section only
3 Not available in 347V
4 EL and EC are installed in last 4’ of luminaire
sections. Separate feed required unless ELS