LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
Type:
________________________
Project:
______________________
1
© 2013 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Prima” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect-Direct T8
PRM4 Prima I/D
Examples:
PRM4 2 32 WHR SSB 40FT R12 120 GEB10 2SE EL SCT LP835 F1/24 C518 — PRM4 3 32 SPR WPB 12FT R8 277 GEB10 DCT LP835 F2/15 C518 GLR
Construction
9” x 3” one-piece cold-rolled steel housing with flat
end plate.
Reflectors
Die-formed highly reflective white or specular
reflector.
Shielding
Semi-specular parabolic aluminum baffles.
Finish
Fine-textured, white paint or silver paint to match
anodized aluminium are standard. Custom colors
available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’
1
⁄
4
”, 8’ and 12’ lengths in a single section for
exact suspension spacing of 4’, 8’ and 12’. For total
luminaire length add
1
⁄
16
” for each end cap. Using
internal joiners, 4’, 8’ and 12’ sections can be joined
to form longer-length luminaires.
Suspended
PRM4
Prima I/D
Indirect-Direct T8
PRM4 - 1
PRM4 - 2
PRM4 - 3
9”
3”
9”
3”
9”
3”
__________
__________
__________
__________
_________
_________
_________
__________
__________
__________
Luminaire
PRM4
# of
Lamps in
Cross
Section
1
2
3
Lamp Type
32
32W T8
Reflector
WHR White
Reflector
(Standard)
SPR Specular
Reflector
Shielding
OPD Baffle
w/std
brightness
opal
diffuser
overlay
Baffle
SSB Semi-
specular
baffle
WPB White
painted
baffle
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
______________
__________
__________
________________
______________
______________
______________
_________________________________
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency
Type
2
(Blank) None
EC Emergency
circuit
EL
1
Emergency
battery pack
EN
1
Emergency
battery pack
w/night light
circuit
Switching
SCT Single
circuit
DCT Dual
circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy
saving lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Referenc
website or consult factory
for other options.
Mounting Type /
F1/
T-bar ceiling (universal
mounting bracket)
F2/
Hard ceiling (horizontal
J-box)
F3/
Rigid stem
Overall
Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall
suspension is
measured from
ceiling to
bottom of
luminaire.
Finish
C110 Painted
aluminum
(low gloss)
C518 White (fine-
textured low
gloss)
C099 Custom finish
Options
ACG
Adjustable cable grippers
BLK
Black cord, cord manager and canopy (not
available with F3)
CP
Chicago plenum (available with F1A only)
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed,
shared neutral
ELS2
Emergency through wiring w/single feed,
separate neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
MCS
Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC
New York City code
OJB
Offset junction box
SLP
Sloped ceiling (for 10-45°, must be specified
with F2, ACG and OJB options)
XXXX Integrated sensor; choose options and obtain
code on page 2
Notes:
1 Not available in 347V
2 EL and EC are installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified