LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Direct T5/T5HO

LLML  Lightline Softshine

Suspended

LLML

Lightline Softshine

Direct

Direct T5/T5HO

Examples:

LLML 1 28T5 SSH 34FT7IN R8 120 GEB10 SCT LP835 F1/18 C100 — LLML 1 28T5 SSH 41FT5IN R8 277 GEB10 1SE EC SCT LP835 F1/24 C041 ACG

Construction

Extruded aluminum housing forms a 3

5

8

” x 4

1

16

rectangular profile. Die-cast aluminum end caps

mechanically attach with no exposed fasteners.

Shielding

Softshine high performance lens controls light

distribution. Uniform luminance along the length of

the lens is achieved with staggered lamps.

Reflectors

High reflectance white painted reflector system.

Finish

Satin anodized finish consists of satin anodized

housing with end caps painted to match. Custom

colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

Stand alone sections are 3’10” (R4), 7’3” (R8), and

10’8” (R12). Rows are comprised of starter, joiner

and ender sections of various lengths. Refer to

planning guide for details. For total luminaire length,

add

7

8

” for each end cap.

__________

__________

__________

__________

_________

__________

__________ __________

Luminaire

LLML

# of Lamps in

Cross Section

1

Lamp Type

28T5 28W T5

54T5HO 54W T5HO

Shielding

SSH Softshine

lens

Luminaire Row Length

1

3FT10IN

7FT3IN

10FT8IN

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

2,3

Advance Mark 10 dim

DMHL3D

2

Lutron Hi-Lume dim

ADZT

2

Advance Mark 7 0-10V dim

OSDIM

2,3

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

______________

_____________

_____________

________________

______________

______________

______________

_________________________________

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency

Type

4

(Blank) None

EC Emergency

circuit

EL

3

Emergency

battery

pack

EN

3

Emergency

battery

pack

w/night

light

circuit

Switching

SCT Single

circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling

(universal mounting

bracket)

F1A/ T-bar ceiling (UMB

with integrated

J-box)

F2/

Hard ceiling

(horizontal J-box)

F3/

Rigid stem

Overall

Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall

suspension is

measured from

ceiling to bottom

of luminaire.

Finish

C041 White

white

(low

gloss)

C100 Satin

anodized

finish

C099 Custom

finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not

available with F3)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed,

shared neutral

ELS2

Emergency through wiring w/single feed,

separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified

with F2, ACG and OJB options)

XXXX Integrated sensor; choose options and obtain

code on page 2

Notes:

1 Available with individual units only (3FT10IN, 7FT3IN, 10FT8IN)

2 Consult factory for row lengths greater than 99FT6IN

3 Not available in 347V

4 Not available with 28T5 lamps

5 Emergency type is installed in last 4’ of luminaire sections. Separate

feed required unless ELS or ELS2 is specified

LLML

3

5

8

4

1

16

14FT1IN

17FT6IN

20FT11IN

24FT4IN

27FT9IN

31FT2IN

34FT7IN

38FT0IN

41FT5IN

44FT10IN

48FT3IN

51FT8IN

55FT1IN

58FT6IN

61FT11IN

65FT4IN

68FT9IN

72FT2IN

75FT7IN

79FT0IN

82FT5IN

85FT10IN

89FT3IN

92FT8IN

96FT1IN

99FT6IN