Peerless Lighting BRM7 - T8 User Manual
Bruno, Partial perforation indirect t8, Suspended
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
BRM7 2 T8 WHR
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T8
BRM7 Bruno Partial Perforation
Examples:
BRM7 2 32 SPR 40FT R8 277 GEB10 DCT LP835 F1/18 C210 SCEP — BRM7 2 32 SPR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110
Suspended
BRM7
SCEP Option
1
3
⁄
4
”
BRM7 - 2
8
1
⁄
4
”
Construction
Nominal 8
1
⁄
4
” x 1
3
⁄
4
” rectangular housing is formed
from cold-rolled steel. Die-cast end caps are
mechanically attached with no exposed fasteners.
Reflectors
Die-formed specular reflector with 95% reflectance.
Shielding
Die-punched perforations with acrylic opal
diffuser overlay.
Finish
Fine-textured, white polyester powder paint
is standard. Consult factory for special finish
requirements.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’
3
⁄
8
”, 8’ and 12’ lengths in a single section for
nominal support spacing at 4’, 8’ and 12’. For total
luminaire length, add
5
⁄
8
” for each flat end cap
and 4” for each sculptured end cap. Using internal
joiners, 4’, 8’ and 12’ sections can be joined to form
longer rows.
__________
__________
__________
__________
_________
__________
__________ __________
__________
__________
Luminaire
BRM7
# of
Lamps in
Cross
Section
2
Lamp Type
32
32W T8
Reflector
SPR Specular
reflector
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
______________
________________
______________
______________
______________
_________________________________
Switching
SCT
Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy saving
lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Referenc
on
website or consult factory
for other options.
Mounting Type /
F1/
T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/
Hard ceiling (horizontal
J-box)
F3/
Rigid stem
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is
measured from ceiling to
bottom of luminaire.
Finish
C110 Painted aluminum
(low gloss)
C210 White white
(fine-textured
low gloss)
C099 Custom finish
Options
ACG
Adjustable cable grippers
BLK
Black cord, cord manager and canopy (not available with F3)
CP
Chicago plenum (available with F1A only)
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2
Emergency through wiring w/single feed, separate neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
MCS
Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC
New York City code
OJB
Offset junction box
SCEP
Sculptured end cap
SLP
Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
XXXX Integrated sensor; choose options and obtain code on page 2
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
Bruno
Partial Perforation
Indirect T8