Peerless Lighting LLWA - T5 User Manual
Lightline wall asymmetric direct, Direct t5, Wall mount
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
3
⁄
8
”
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Direct T5
Examples:
LLWA D 1 28T5 SSB 40FT R8 277 GEB10 SCT LP835 C100 — LLWA X 1 28T5 WPB 40FT R8 120 GEB10 1SE EC SCT LP835 C041
Wall Mount
LLWA
Lightline Wall
Asymmetric Direct
Direct T5
Construction
Extruded aluminum housing forms a 3
5
⁄
8
” x 4
1
⁄
16
”
rectangular profile. Die-cast aluminum end caps
mechanically attach with no exposed fasteners.
Extended arm mount (Mounting Type “X”) is
extruded aluminum extending 21”.
Shielding
Arc-shaped, parabolic low iridescent semi-specular
or white painted aluminum louver.
Reflectors
High reflectance white painted reflector system.
Finish
Satin anodized finish consists of satin anodized
housing with end caps painted to match. Custom
colors available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section. For total
luminaire length, add
7
⁄
8
” for each end cap. Using
internal joiners, 4’, 8’, and 12’ sections can be joined
to form longer length luminaires.
__________
__________
__________
__________
_________
_________
__________
__________
__________
__________
Luminaire
LLWA
Mounting Type
D
Wall spacer
X 21”
extended
arm mount
# of Lamps in
Cross Section
1
Lamp Type
28T5 28W T5
Baffle
SSB Semi
specular
baffle
WPB White
painted
baffle
Luminaire
Row Length
X FT
(4’ increments)
Maximum
Section Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1
Osram 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
______________
________________
________________
______________
_________________________________
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Available with T5 only:
LP830P 3000K 80+ CRI Premier
LP835P 3500K 80+ CRI Premier
LP841P 4100K 80+ CRI Premier
Referenc
consult factory for other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
DL
Damp location label
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
LLWA D
LLWA X
3
5
⁄
8
”
3
5
⁄
8
”
4
1
⁄
16
”
4
1
⁄
16
”
21”
LLWA Lightline Wall Asymmetric