beautypg.com

Peerless Lighting LLWA - T5 User Manual

Lightline wall asymmetric direct, Direct t5, Wall mount

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

3

8

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Direct T5

Examples:

LLWA D 1 28T5 SSB 40FT R8 277 GEB10 SCT LP835 C100 — LLWA X 1 28T5 WPB 40FT R8 120 GEB10 1SE EC SCT LP835 C041

Wall Mount

LLWA

Lightline Wall

Asymmetric Direct

Direct T5

Construction

Extruded aluminum housing forms a 3

5

8

” x 4

1

16

rectangular profile. Die-cast aluminum end caps

mechanically attach with no exposed fasteners.

Extended arm mount (Mounting Type “X”) is

extruded aluminum extending 21”.

Shielding

Arc-shaped, parabolic low iridescent semi-specular

or white painted aluminum louver.

Reflectors

High reflectance white painted reflector system.

Finish

Satin anodized finish consists of satin anodized

housing with end caps painted to match. Custom

colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’, and 12’ lengths in a single section. For total

luminaire length, add

7

8

” for each end cap. Using

internal joiners, 4’, 8’, and 12’ sections can be joined

to form longer length luminaires.

__________

__________

__________

__________

_________

_________

__________

__________

__________

__________

Luminaire

LLWA

Mounting Type

D

Wall spacer

X 21”

extended

arm mount

# of Lamps in

Cross Section

1

Lamp Type

28T5 28W T5

Baffle

SSB Semi

specular

baffle

WPB White

painted

baffle

Luminaire

Row Length

X FT

(4’ increments)

Maximum

Section Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

________________

________________

______________

_________________________________

Emergency Type

2

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery pack

EN

1

Emergency battery pack

w/night light circuit

Switching

SCT

Single circuit

Lamp Color

L/LP No lamp

LP830 3000K 80+ CRI

LP835 3500K 80+ CRI

LP841 4100K 80+ CRI

Available with T5 only:

LP830P 3000K 80+ CRI Premier

LP835P 3500K 80+ CRI Premier

LP841P 4100K 80+ CRI Premier
Reference

Lamp Chart

on website or

consult factory for other options.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

DL

Damp location label

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

NYC New York City code

Notes:

1 Not available in 347V

2 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

LLWA D

LLWA X

3

5

8

3

5

8

4

1

16

4

1

16

21”

LLWA  Lightline Wall Asymmetric